Literature DB >> 28459285

A validation study of reconstructed rapid prototyping models produced by two technologies.

Christian Andreas Dietrich, Andreas Ender, Stefan Baumgartner, Albert Mehl.   

Abstract

OBJECTIVE: To determine the accuracy (trueness and precision) of two different rapid prototyping (RP) techniques for the physical reproduction of three-dimensional (3D) digital orthodontic study casts, a comparative assessment using two 3D STL files of two different maxillary dentitions (two cases) as a reference was accomplished.
MATERIALS AND METHODS: Five RP replicas per case were fabricated using both stereolithography (SLA) and the PolyJet system. The 20 reproduced casts were digitized with a highly accurate reference scanner, and surface superimpositions were performed. Precision was measured by superimposing the digitized replicas within each case with themselves. Superimposing the digitized replicas with the corresponding STL reference files assessed trueness. Statistical significance between the two tested RP procedures was evaluated with independent-sample t-tests (P < .05).
RESULTS: The SLA and PolyJet replicas showed statistically significant differences for trueness and precision. The precision of both tested RP systems was high, with mean deviations in stereolithographic models of 23 (±6) μm and in PolyJet replicas of 46 (±13) μm. The mean deviation for trueness in stereolithographic replicas was 109 (±4) μm, while in PolyJet replicas, it was 66 (±14) μm.
CONCLUSIONS: Comparing the STL reference files, the PolyJet replicas showed higher trueness than the SLA models. But the precision measurements favored the SLA technique. The dimensional errors observed in this study were a maximum of 127 μm. In the present study, both types of reproduced digital orthodontic models are suitable for diagnostics and treatment planning.

Keywords:  3D printing; Dental casts; Rapid prototyping; Stereolithography

Mesh:

Year:  2017        PMID: 28459285     DOI: 10.2319/01091-727.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  15 in total

1.  [A method to evaluate the trueness of reconstructed dental models made with photo-curing 3D printing technologies].

Authors:  N Xiao; Y C Sun; Y J Zhao; Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-02-18

2.  Accuracy evaluation of bracket repositioning by indirect bonding: hard acrylic CAD/CAM versus soft one-layer silicone trays, an in vitro study.

Authors:  Thomas Pottier; Antoine Brient; Yann Loïg Turpin; Brice Chauvel; Vincent Meuric; Olivier Sorel; Damien Brezulier
Journal:  Clin Oral Investig       Date:  2020-03-31       Impact factor: 3.573

3.  A Method for Tooth Model Reconstruction Based on Integration of Multimodal Images.

Authors:  Xinwen Zhou; Yangzhou Gan; Jing Xiong; Dongxia Zhang; Qunfei Zhao; Zeyang Xia
Journal:  J Healthc Eng       Date:  2018-06-20       Impact factor: 2.682

4.  Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation.

Authors:  Tim Joda; Lea Matthisson; Nicola U Zitzmann
Journal:  J Clin Med       Date:  2020-05-12       Impact factor: 4.241

5.  Accuracy of different tooth surfaces on 3D printed dental models: orthodontic perspective.

Authors:  Ting Dong; Xiaoting Wang; Lunguo Xia; Lingjun Yuan; Niansong Ye; Bing Fang
Journal:  BMC Oral Health       Date:  2020-11-25       Impact factor: 2.757

6.  Three-dimensional evaluation of the transfer accuracy of a bracket jig fabricated using computer-aided design and manufacturing to the anterior dentition: An in vitro study.

Authors:  Jae-Hyun Park; Jin-Young Choi; Seong-Hun Kim; Su-Jung Kim; Kee-Joon Lee; Gerald Nelson
Journal:  Korean J Orthod       Date:  2021-11-25       Impact factor: 1.372

Review 7.  3D Printing in Digital Prosthetic Dentistry: An Overview of Recent Developments in Additive Manufacturing.

Authors:  Josef Schweiger; Daniel Edelhoff; Jan-Frederik Güth
Journal:  J Clin Med       Date:  2021-05-07       Impact factor: 4.964

8.  In vitro accuracies of 3D printed models manufactured by two different printing technologies.

Authors:  Faruk Emir; Gulsum Ceylan; Simel Ayyildiz
Journal:  Eur Oral Res       Date:  2021-05-04

9.  Morphological validation of a novel bi-material 3D-printed model of temporal bone for middle ear surgery education.

Authors:  Jordan Chauvelot; Cedric Laurent; Gaël Le Coz; Jean-Philippe Jehl; Nguyen Tran; Marta Szczetynska; Abdelhadi Moufki; Anne-Sophie Bonnet; Cecile Parietti-Winkler
Journal:  Ann Transl Med       Date:  2020-03

10.  Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners.

Authors:  Samer T Jaber; Mohammad Y Hajeer; Tarek Z Khattab; Luai Mahaini
Journal:  Clin Exp Dent Res       Date:  2020-11-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.