Markus Riedl1, Richard R Glisson2, Takumi Matsumoto3, Stefan G Hofstaetter4, Mark E Easley5. 1. Wilhelminen Hospital, Department of Trauma Surgery, Montleartstraße 37, 1160 Wien, Austria. Electronic address: markus.riedl@wienkav.at. 2. Duke University Medical Center, Department of Orthopaedic Surgery, P.O. Box 3093, Durham, NC 27710, USA. Electronic address: r.r.glisson@duke.edu. 3. The University of Tokyo, Department of Orthopaedic Surgery, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan. Electronic address: matumot-tky@umin.ac.jp. 4. Hospital Klinikum Wels-Grieskirchen, Department of Orthopaedic Surgery, Grieskirchner Street 42, 4600 Wels, Austria. Electronic address: stefan.hofstaetter@klinikum-wegr.at. 5. Duke University Medical Center, Department of Orthopaedic Surgery, 4709 Creekstone Drive, Durham, NC 27703, USA. Electronic address: mark.e.easley@dm.duke.edu.
Abstract
BACKGROUND: Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. METHODS: Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. FINDINGS: Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. INTERPRETATION: Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion.
BACKGROUND:Subtalar joint arthrodesis is a common operative treatment for symptomatic subtalar arthrosis. Because excessive relative motion between the talus and calcaneus can delay or prohibit fusion, fixation should be optimized, particularly in patients at risk for subtalar arthrodesis nonunion. Tapered, fully-threaded, variable pitch screws are gaining popularity for this application, but the mechanical properties of joints fixed with these screws have not been characterized completely. We quantified the torsion resistance of 2-screw and 3-screw subtalar joint fixation using this type of screw. METHODS: Ten pairs of cadaveric subtalar joints were prepared for arthrodesis and fixed using Acutrak 2-7.5 screws. One specimen from each pair was fixed with two diverging posterior screws, and the contralateral joint was fixed using two posterior screws and a third screw directed through the anterior calcaneus into the talar neck. Internal and external torsional loads were applied and joint rotation and torsional stiffness were measured at two torque levels. FINDINGS:Internal rotation was significantly less in specimens fixed with three screws. No difference was detectable between 2-screw and 3-screw fixation in external rotation or torsional stiffness in either rotation direction. Both 2-screw and 3-screw fixation exhibited torsion resistance surpassing that reported previously for subtalar joints fixed with two diverging conventional lag screws. INTERPRETATION: Performance of the tapered, fully threaded, variable pitch screws exceeded that of conventional lag screws regardless of whether two or three screws were used. Additional resistance to internal rotation afforded by a third screw placed anteriorly may offer some advantage in patients at risk for nonunion.
Authors: Nileshkumar Chaudhari; Alexandre Leme Godoy-Santos; Cesar de Cesar Netto; Ramon Rodriguez; Shouchen Dun; Jun Kit He; Haley McKissack; Glenn S Fleisig; Eduardo Araujo Pires; Ashish Shah Journal: Einstein (Sao Paulo) Date: 2020-03-06