Literature DB >> 28456559

Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell.

Ronald E Delanois1, Chukwuweike U Gwam1, Nequesha Mohamed1, Anton Khlopas2, Morad Chughtai2, Arthur L Malkani3, Michael A Mont2.   

Abstract

BACKGROUND: We are reporting on the minimum 5-year outcomes of patients who underwent revision total hip arthroplasty (THA) using a specific highly-porous titanium shell. We assessed (1) aseptic and all-cause survivorship; (2) functional outcomes; (3) complications; and (4) radiographic outcomes.
METHODS: Two hospital databases were evaluated for patients who underwent revision THA due to component instability or aseptic loosening using a cementless highly-porous titanium shell between September 2006 and December 2011. This yielded 35 patients who had a mean age of 61 years (range 14-88 years). Patients had a mean follow-up of 6 years (minimum 5 years). All-cause and aseptic survivorship of the shell was calculated. Functional outcomes were assessed using the Harris Hip Score. We determined the incidence of postoperative complications and performed radiographic evaluation of pelvic radiographs from regular office visits. RESULT: The aseptic survivorship of the acetabular component was 97% (95% confidence interval; 8.1-9.5). The all-cause survivorship of the acetabular component was 91% (95% confidence interval; 7.3-8.1). One patient had an aseptic failure and 2 patients had septic failures. The mean postoperative Harris Hip Score was 76 points (range, 61-91 points). Excluding the aseptic and septic failures, there was no osteolysis or progressive radiolucencies present on radiographic evaluation at final follow-up.
CONCLUSION: At a minimum of 5-year follow-up, the highly-porous titanium acetabular revision shell has excellent survivorship and functional outcomes. Although long-term follow-up is needed to further monitor these implants, the results are promising and demonstrate that this prosthesis may be an excellent option for patients undergoing revision THA.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  THA; hip arthroplasty; midterm outcomes; revision THA; revision hip arthroplasty

Mesh:

Substances:

Year:  2017        PMID: 28456559     DOI: 10.1016/j.arth.2017.03.065

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  3 in total

1.  Minimum 2-Year Outcomes of a Novel 3D-printed Fully Porous Titanium Acetabular Shell in Revision Total Hip Arthroplasty.

Authors:  Elyse J Berlinberg; J Abraham Kavian; Mackenzie A Roof; Ittai Shichman; Brett Frykberg; William B Lutes; Erik A Schnaser; Stephen A Jones; Richard W McCalden; Ran Schwarzkopf
Journal:  Arthroplast Today       Date:  2022-10-12

2.  Mid-term outcomes of tantalum cup- a single centre study.

Authors:  Rajesh Bawale; Baseem Choudhry; Srinivasa Samsani
Journal:  Arthroplasty       Date:  2021-10-09

3.  Comparison of the Primary Stability of Porous Tantalum and Titanium Acetabular Revision Constructs.

Authors:  Nicholas A Beckmann; Rudi G Bitsch; Mareike Schonhoff; Klaus-Arno Siebenrock; Martin Schwarze; Sebastian Jaeger
Journal:  Materials (Basel)       Date:  2020-04-10       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.