Literature DB >> 28455225

Temporal and spatiotemporal variability in comprehensive forearm skin microcirculation assessment during occlusion protocols.

Tomas Strömberg1, Folke Sjöberg2, Sara Bergstrand3.   

Abstract

Forearm skin hyperemia during release after brachial occlusion has been proposed for evaluating peripheral arterial disease and endothelial dysfunction. We used a novel fiberoptic system integrating Laser Doppler Flowmetry and Diffuse Reflectance Spectroscopy for a comprehensive pointwise model based microcirculation characterization. The aim was to evaluate and compare the temporal and the spatiotemporal variabilities in forearm skin microcirculation parameters (speed resolved perfusion; low speed <1mm/s, PerfSR, <1; mid-speed 1-10mm/s, high speed >10mm/s, and total perfusion (PerfSR, tot); the concentration and oxygenation of red blood cells, CRBC and SO2). Ten healthy subjects underwent arterial and venous forearm occlusions (AO, VO), repeated within one week. The repeatability was calculated as the coefficient of variation (CV) and the agreement as the intra-class correlation coefficient (ICC). The temporal CVs for conventional perfusion, Perfconv, PerfSR, tot, CRBC and SO2 were 14%, 12%, 9% and 9%, respectively, while the ICC were >0.75 (excellent). The perfusion measures generally had a higher spatiotemporal than temporal variability, which was not the case for SO2 and CRBC. The corresponding spatiotemporal CVs were 33%, 32%, 18% and 15%, respectively. During VO, CRBC had a CV<35% and ICC>0.40 (fair-good), and after release this was the case for CRBC (AO and VO), SO2 (VO) and PerfSR, <1 (VO). In conclusion, the skin microcirculation parameters showed excellent temporal repeatability, while the spatiotemporal repeatability especially for perfusion was poorer. The parameters with acceptable repeatability and fair-good agreement were: CRBC during and after release of VO, the PerfSR, <1 after release of VO, the SO2 and the CRBC after release of AO. However, the value of these parameters in discriminating endothelial function remains to be studied.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Diffuse reflectance spectroscopy; Laser Doppler flowmetry; Perfusion; Tissue oxygenation; Vascular occlusion

Mesh:

Substances:

Year:  2017        PMID: 28455225     DOI: 10.1016/j.mvr.2017.04.005

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  3 in total

1.  Normative data and the influence of age and sex on microcirculatory function in a middle-aged cohort: results from the SCAPIS study.

Authors:  Hanna Jonasson; Sara Bergstrand; Ingemar Fredriksson; Marcus Larsson; Carl Johan Östgren; Tomas Strömberg
Journal:  Am J Physiol Heart Circ Physiol       Date:  2020-03-06       Impact factor: 4.733

2.  Validation of speed-resolved laser Doppler perfusion in a multimodal optical system using a blood-flow phantom.

Authors:  Hanna Jonasson; Ingemar Fredriksson; Marcus Larsson; Tomas Strömberg
Journal:  J Biomed Opt       Date:  2019-09       Impact factor: 3.170

3.  Impact of local thermal stimulation on the correlation between oxygen saturation and speed-resolved blood perfusion.

Authors:  Guangjun Wang; Shuyong Jia; Mi Liu; Xiaojing Song; Hongyan Li; Xiaorong Chang; Weibo Zhang
Journal:  Sci Rep       Date:  2020-01-13       Impact factor: 4.379

  3 in total