Three-dimensional surface scanners compared with standard anthropometric measurements for head shape.

Caroline A A Beaumont1, Paul G M Knoops2, Alessandro Borghi2, N U Owase Jeelani2, Maarten J Koudstaal3, Silvia Schievano2, David J Dunaway2, Naiara Rodriguez-Florez2.   

Abstract

Three-dimensional (3D) surface imaging devices designed to capture and quantify craniofacial surface morphology are becoming more common in clinical environments. Such scanners overcome the limitations of two-dimensional photographs while avoiding the ionizing radiation of computed tomography. The purpose of this study was to compare standard anthropometric cranial measurements with measurements taken from images acquired with 3D surface scanners. Two 3D scanners of different cost were used to acquire head shape data from thirteen adult volunteers: M4D scan and Structure Sensor. Head circumference and cephalic index were measured directly on the patients as well as on 3D scans acquired with the two scanners. To compare head volume measurements with a gold standard, magnetic resonance imaging scans were used. Repeatability and accuracy of both devices were evaluated. Intra-rater repeatability for both scanners was excellent (intraclass correlation coefficients > 0.99, p < 0.001). Direct and digital measures of head circumference, cephalic index and head volume were strongly correlated (0.85 < r < 0.91, p < 0.001). Compared to direct measurements, accuracy was highest for M4D scan. Both 3D scanners provide reproducible data of head circumference, cephalic index and head volume and show a strong correlation with traditional measurements. However, care must be taken when using absolute values.
Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Anthropometry; Craniofacial surgery; Maxillofacial surgery; Three-dimensional imaging; Three-dimensional surface scanning

Mesh:

Year:  2017        PMID: 28454666     DOI: 10.1016/j.jcms.2017.03.003

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  2 in total

1.  A comparative study between traditional head measurement and structured light three-dimensional scanning when measuring infant head shape.

Authors:  Zhi-Feng Wu; Qiong-Li Fan; Li Ming; Wang Yang; Kui-Lin Lv; Qin Chang; Wen-Zao Li; Cheng-Ju Wang; Qiu-Ming Pan; Li He; Bin Hu; Yu-Ping Zhang
Journal:  Transl Pediatr       Date:  2021-11

2.  Effect of Ambient Lights on the Accuracy of a 3-Dimensional Optical Scanner for Face Scans: An In Vitro Study.

Authors:  Punrit Thongma-Eng; Pokpong Amornvit; Patcharawan Silthampitag; Dinesh Rokaya; Attavit Pisitanusorn
Journal:  J Healthc Eng       Date:  2022-08-05       Impact factor: 3.822

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.