| Literature DB >> 28454586 |
Jo-Hui Pan1, Chiung-Yu Peng2, Chung-Ting Lo3, Chia-Yen Dai3,4, Chao-Ling Wang3, Hung-Yi Chuang3,2.
Abstract
BACKGROUND: n-Hexane is a well-known neurotoxicant. Polyneuropathy due to occupational n-hexane exposure has been reported worldwide, however, our case is the first report in the Chinese herb industry. CASEEntities:
Keywords: Chinese medicine pharmaceutical plant; Neuropathy; Occupational exposure; Solvent; n-hexane
Mesh:
Substances:
Year: 2017 PMID: 28454586 PMCID: PMC5410082 DOI: 10.1186/s13256-017-1280-9
Source DB: PubMed Journal: J Med Case Rep ISSN: 1752-1947
Electromyography data
| Side | Muscle tested | Insertional activity | Spontaneous activity | Motor unit | Recruitment | Interference | |||
|---|---|---|---|---|---|---|---|---|---|
| Fibs | Psw | Amp | Dur | Poly | |||||
| Right | Anterior tibialis | - | +/- | +/- | - | - | 3+ | ↓ | - |
| Right | Extensor digitorum brevis | - | 2+ | 2+ | - | - | 3+ | ↓ | - |
| Right | Rectus femoris | - | - | - | - | - | 2+ | ↓ | - |
| Right | First dorsal interosseous | - | - | - | - | - | 3+ | ↓ | - |
| Right | Biceps (long head) | - | - | - | - | - | 0 | - | - |
- negative finding, Amp amplitude, Dur duration, Fibs fibrillation potentials, Poly polyphasic potentials, Psw positive sharp waves, ↓ reduced
Nerve conduction velocity data
| Motor nerve conduction studies | Sensory nerve conduction study | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Nerve | Segment | Latency (ms) | Amplitude (μV) | Velocity (m/s) | Nerve | Site | Latency (ms) | Amplitude (μV) | Velocity (m/s) |
| Median (left/right) | W | 6.7/6.6 | 5.4/4.7 | Median (left/right) | W | 4.4/4.8 | 33.7/25.1 | NA | |
| W-E | 11.2/11.1 | 4.2/4.4 | 42/44 | P | 2.0/2.1 | 60.2/55.1 | NA | ||
| F-wave | 31.16/32.67 | Ulnar (left/right) | W | 3.9/3.7 | 22.7/18.5 | NA | |||
| Ulnar (left/right) | W | 4.7/4.8 | 6.6/4.1 | ||||||
| W-E | 8.5/8.5 | 6.0/3.4 | 42/43 | Radial (left/right) | W | 3.3/3.4 | 20.1/15.7 | NA | |
| BE-AE | 10.7/10.9 | 6.1/3.3 | 45/42 | ||||||
| F-wave | 30.54/30.66 | Sural (left/right) | C | 4.5/4.5 | 6.1/7.2 | NA | |||
| Radial (left/right) | BE | 2.3/2.3 | 5.8/5.4 | ||||||
| BE-AE | 4.8/4.8 | 6.0/4.7 | 40/40 | H reflex study | |||||
| Peroneal (left/right) | A | 7.8/7.7 | 1.5/2.1 | Nerve | Latency (ms) | ||||
| A-BF | 18.3/18.2 | 1.0/0.4 | 28/29 | Tibial (left/right) | NP/NP | ||||
| F-wave | 53.9/NP | ||||||||
| Tibial (left/right) | A | 5.6/5.9 | 5.7/6.1 | ||||||
| A-K | 18.5/18.1 | 1.9/2.3 | 31/32 | ||||||
| F-wave | 64.82/64.35 | ||||||||
A ankle, AE above elbow, BE below elbow, BF below fibular head, C calf, E elbow, K knee, NA not available, NP no potential evoked, P palm, W wrist
Fig. 1Timeline of the clinical course of the case. The patient’s symptoms began with numbness of his hands 6 months after starting a job. His symptom progressed and was accompanied with distal weakness in the following 10 months. After removal of occupational exposure to n-hexane for 4 months, his symptoms subsided and he returned to work in another section of the plant that had no n-hexane exposure
Fig. 2The role of n-hexane in the mixing process. ➀ Pour the n-hexane into the tank with extract and gel inside. ➁ Stirring by machine. ➂ The n-hexane volatilized and formation of gluey ointment
Fig. 3The sampling sites in the workplace. There were four mixers in the mixing room, but only one is working. We placed sample 1 near the stirring barrel tank, sample 2 near the exhaust pipe, and sample 3 on the operator
The sampling result of n-hexane concentration in the air in the mixing room
| Sample number | Sampling type | Flow rate (ml/minute) | Sampling time (minutes) | Sampling volume (m3) | Adsorbed mass (mg) | Concentration | ||
|---|---|---|---|---|---|---|---|---|
| During sampling | NTP | (mg/ m3) | (ppm) | |||||
| 1 | Workplacea | 100.0 | 59 | 0.005900 | 0.005836 | 36.79 | 6304 | 1789 |
| 2 | Workplaceb | 100.6 | 49 | 0.004929 | 0.004876 | 7.83 | 1607 | 456 |
| 3 | Personal | 98.4 | 59 | 0.005806 | 0.005742 | 2.42 | 422 | 120 |
NTP normal temperature and pressure. aThis sample placed near the stirring barrel tank had breakthrough. bThis sample was placed on the wall near the exhaust pipe