| Literature DB >> 28451810 |
Helen McLeod1, Ben F Cox2, James Robertson1, Robyn Duncan3, Shona Matthew1, Raj Bhat4, Avril Barclay4, J Anwar4, Tracey Wilkinson3, Andreas Melzer2, J Graeme Houston5.
Abstract
PURPOSE: The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing.Entities:
Keywords: Cadaveric perfusion; Endovascular aortic aneurysm repair (EVAR); Endovascular training
Mesh:
Year: 2017 PMID: 28451810 PMCID: PMC5541076 DOI: 10.1007/s00270-017-1643-z
Source DB: PubMed Journal: Cardiovasc Intervent Radiol ISSN: 0174-1551 Impact factor: 2.740
Pressure assessment during standard flow conditions (mmHg)
| MAP cadaver 1 | MAP cadaver 2 | |
|---|---|---|
| Arch of aorta | 38.8 | 52 |
| Distal aorta | 37.5 | 54 |
| Extracorporeal | 78.1 | 110 |
Imaging parameters
| Modality | Equipment | Settings | Contrast |
|---|---|---|---|
| X-ray fluoroscopy | OEC Elite 9900 C Arm (GE, USA) | Fluoroscopic imaging 8–12 f.p.s and digital subtraction angiography 25 f.p.s | 20-ml Bolus contrast (Omnipaque 300, GE Healthcare, Auckland) was introduced manually |
| CT | Siemens Biograph mCT scanner (Siemens, Erlangen DE) | Slice thickness 0.6 mm, pitch 0.8, kV 120. Effective mat rotation time, 0.5 s. | Bolus-tracked contrast was initiated manually (Omnipaque 300, GE Healthcare, New Zealand). |
Fig. 1Post-procedure CT scan. CT angiogram (Table 1), MIP 3D reconstruction, allowing vessel and device evaluation (arrows point at post-mortem devices unrelated to this work). A Thoracic stent and abdominal stent conducted under fluoroscopic guidance, B thoracic stent in situ
Fig. 2Valiant thoracic stent graft Captivia Delivery System intervention to the thoracic aorta of a Thiel-embalmed human cadaver. A Digital subtraction angiography cadaveric aorta with Captivia catheter located in the descending aorta. B Fluoroscopic-guided catheter advanced to position in cadaveric aortic arch. Arrows points to ring and swab placed during post-mortem training which was not related to this procedure. C Stent graft deployed in the thoracic aorta. D Catheter undocked and withdrawn. E Guide wire remains in device to allow angiographic catheter to be placed in aorta. F Post-procedure digital subtraction angiography demonstrating patent aorta
Fig. 3Stent graft intervention to abdominal aorta of Thiel-embalmed human cadaver (thoracic Valiant device and Captivia Delivery System used to demonstrate viability of technique). A ipsilateral catheter placement—DSA aortogram [Table 1). Renal arteries evident to plan location of device deployment, B DSA Captivia catheter evident, located in aorta to deliver device to infra-renal position, C fluoroscopic image of catheter in situ, D Valiant stent graft being deployed under fluoroscopic guidance, E guide wire remains in device to allow angiographic catheter to be placed in aorta, F post-procedure DSA of distal abdominal aorta and left iliac artery which branches distally into internal and external iliac artery. Right iliac occluded by stent graft and therefore not visible on image
Fig. 4Bifurcating Endurant stent graft intervention to Thiel-embalmed human cadaver. A Fluoroscopic image of pigtail angiographic catheter advancing over guide wire from common femoral artery access paint. B Pre-deployment digital subtraction angiography showing renal arteries and superior mesenteric artery. C Catheter advanced to desired location to locate device in an infra-renal position. D Contralateral leg deployment, catheter advanced to dock into device. Leg deployed, E post-procedure DSA demonstrating patent device
Aortic stent grafts used during the procedures
| Fig. No. | Device | Dimensions (mm) | Size | Implant location |
|---|---|---|---|---|
| Figure | Valiant thoracic | 204 × 30 | 22Fr | Thoracic aorta |
| Valiant thoracic | 164 × 30 | 22Fr | Thoracic aorta | |
| Figure | Valiant thoracic | 124 × 30 | 22Fr | Distal abdominal aorta |
| Endurant II system | 181 × 28 | Abdominal aorta—bifurcating to L& R iliac arteries | ||
| Figure | Endurant II system | 9319 to 13 | Abdominal aorta—iliac artery |