Universal Head Ultrasound Screening in Full-term Neonates: A Retrospective Analysis of 6771 Infants.

Elisa Ballardini1, Anna Tarocco2, Chiara Rosignoli1, Alessandro Baldan1, Caterina Borgna-Pignatti1, Giampaolo Garani3.   

Abstract

BACKGROUND: Full-term neonates may have asymptomatic cranial injuries at birth and head ultrasound screening could be useful for early diagnosis. The aim of this study was to assess the prevalence and type of intracranial abnormalities and the usefulness of head ultrasound screening in these infants.
METHODS: Head ultrasound screening was performed on all full-term neonates (gestational age between 37 and 42 weeks), born at Sant'Anna University Hospital of Ferrara, Italy, from June 1, 2008 through May 31, 2013. Ultrasound findings were categorized into three groups: normal, minor, and major anomalies.
RESULTS: All full-term neonates (6771) born at our hospital underwent head ultrasound screening. One hundred fourteen of 6771 (1.7%) presented ultrasound abnormalities, whereas 6657 were normal or exhibited insignificant findings. In 101 of 114 (88.6%), abnormalities were minor, and only 13 infants had major abnormalities (0.19% of all full-term newborns). All neonates with major abnormalities presented with either microcephaly or abnormal neurological evaluations. Only one individual with major abnormalities was detected exclusively by ultrasound.
CONCLUSIONS: The number of significant anomalies detected by head ultrasound screening in asymptomatic full-term neonates born during the study period was low. Therefore, there is no indication for routine general head ultrasound screening in these patients. However, even if low, in neonates who have neurological abnormalities, risk factors or suspected brain malformations, head ultrasound screening may play an important role in the early diagnosis of intracranial anomalies.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  brain imaging; newborn screening; term infants; ultrasonography

Mesh:

Year:  2017        PMID: 28449983     DOI: 10.1016/j.pediatrneurol.2017.03.012

Source DB:  PubMed          Journal:  Pediatr Neurol        ISSN: 0887-8994            Impact factor:   3.372


  2 in total

1.  Analyses of pathological cranial ultrasound findings in neonates that fall outside recent indication guidelines: results of a population-based birth cohort: survey of neonates in Pommerania (SNiP-study).

Authors:  Judith Weise; Matthias Heckmann; Hagen Bahlmann; Till Ittermann; Heike Allenberg; Grzegorz Domanski; Anja Erika Lange
Journal:  BMC Pediatr       Date:  2019-12-05       Impact factor: 2.125

2.  Neonatal Neuroimaging in Neonatal Intensive Care Graduates Who Subsequently Develop Cerebral Palsy.

Authors:  Malcolm R Battin; Sîan A Williams; Anna Mackey; Woroud Alzaher; Alexandra Sorhage; N Susan Stott
Journal:  J Clin Med       Date:  2022-03-28       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.