Literature DB >> 28445908

Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose.

Bernhard Petritsch, Aleksander Kosmala, Tobias Gassenmaier, Andreas Max Weng, Simon Veldhoen, Andreas Steven Kunz, Thorsten Alexander Bley.   

Abstract

Purpose To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. Materials and Methods 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Results Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Conclusion Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Key Points: · Dual-energy CT with 90/Sn150 kV configuration allows for significant dose reduction in pulmonary CTA.. · Subjective image quality was similar among the three evaluated CT-protocols (64-slice SSCT, single-energy DSCT, 90/Sn150 kV DECT) and was rated good to excellent in 75% of cases.. · Dual-energy CT provides potential additional information by means of iodine distribution maps.. Citation Format · Petritsch B, Kosmala A, Gassenmaier T et al. Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose. Fortschr Röntgenstr 2017; 189: 527 - 536. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28445908     DOI: 10.1055/s-0043-103089

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  7 in total

Review 1.  State-of-the-Art Imaging for the Evaluation of Pulmonary Embolism.

Authors:  Leonid Roshkovan; Harold Litt
Journal:  Curr Treat Options Cardiovasc Med       Date:  2018-08-07

2.  Head and neck single- and dual-energy CT: differences in radiation dose and image quality of 2nd and 3rd generation dual-source CT.

Authors:  Lukas Lenga; Marvin Lange; Simon S Martin; Moritz H Albrecht; Christian Booz; Ibrahim Yel; Christophe T Arendt; Thomas J Vogl; Doris Leithner
Journal:  Br J Radiol       Date:  2021-04-29       Impact factor: 3.039

Review 3.  Acute Pulmonary Embolism: Prognostic Role of Computed Tomography Pulmonary Angiography (CTPA).

Authors:  Giulia Zantonelli; Diletta Cozzi; Alessandra Bindi; Edoardo Cavigli; Chiara Moroni; Silvia Luvarà; Giulia Grazzini; Ginevra Danti; Vincenza Granata; Vittorio Miele
Journal:  Tomography       Date:  2022-02-14

4.  Role of CT Images in the Diagnosis of Common Acute Abdominal Diseases in General Surgery.

Authors:  Yunguang Nan; Zuyan Zhang; Jianbo Zhang; Bo Jiang; Yuxi Zhu; Li Zhang
Journal:  J Healthc Eng       Date:  2022-03-23       Impact factor: 2.682

5.  Split-filter dual-energy CT pulmonary angiography for the diagnosis of acute pulmonary embolism: a study on image quality and radiation dose.

Authors:  Bernhard Petritsch; Pauline Pannenbecker; Andreas M Weng; Jan-Peter Grunz; Simon Veldhoen; Thorsten A Bley; Aleksander Kosmala
Journal:  Quant Imaging Med Surg       Date:  2021-05

6.  Quantitative Dual-Energy Computed Tomography Predicts Regional Perfusion Heterogeneity in a Model of Acute Lung Injury.

Authors:  Fernando Uliana Kay; Marcelo A Beraldo; Maria A M Nakamura; Roberta De Santis Santiago; Vinicius Torsani; Susimeire Gomes; Rollin Roldan; Mauro R Tucci; Suhny Abbara; Marcelo B P Amato; Edson Amaro
Journal:  J Comput Assist Tomogr       Date:  2018 Nov/Dec       Impact factor: 1.826

7.  Dual-energy CT angiography in suspected pulmonary embolism: influence of injection protocols on image quality and perfused blood volume.

Authors:  Aleksander Kosmala; Philipp Gruschwitz; Simon Veldhoen; Andreas Max Weng; Bernhard Krauss; Thorsten Alexander Bley; Bernhard Petritsch
Journal:  Int J Cardiovasc Imaging       Date:  2020-06-06       Impact factor: 2.357

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.