Literature DB >> 28445847

To elute or not to elute in immunocapture bottom-up LC-MS.

Maren Christin Stillesby Levernæs1, Marianne Nordlund Broughton2, Léon Reubsaet3, Trine Grønhaug Halvorsen4.   

Abstract

Immunocapture-based bottom-up LC-MS is a promising technique for the quantification of low abundant proteins. Magnetic immunocapture beads provide efficient enrichment from complex samples through the highly specific interaction between the target protein and its antibody. In this article, we have performed the first thorough comparison between digestion of proteins while bound to antibody coated beads versus after elution from the beads. Two previously validated immunocapture based MS methods for the quantification of pro-gastrin releasing peptide (ProGRP) and human chorionic gonadotropin (hCG) were used as model systems. The tryptic peptide generation was shown to be protein dependent and influenced by protein folding and accessibility towards trypsin both on-beads and in the eluate. The elution of proteins bound to the beads was also shown to be incomplete. In addition, the on-beads digestion suffered from non-specific binding of the trypsin generated peptides. A combination of on-beads digestion and elution may be applied to improve both the quantitative (peak area of the signature peptides) and qualitative yield (number of missed cleavages, total number of identified peptides, coverage, signal intensity and number of zero missed cleavage peptides) of the target proteins. The quantitative yield of signature peptides was shown to be reproducible in all procedures tested.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomarker quantification; Coverage mapping; Digestion; Magnetic beads; Protein analysis

Mesh:

Substances:

Year:  2017        PMID: 28445847     DOI: 10.1016/j.jchromb.2017.03.044

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

1.  Immunocapture sample clean-up in determination of low abundant protein biomarkers - a feasibility study of peptide capture by anti-protein antibodies.

Authors:  Maren C S Levernæs; Bassem Farhat; Inger Oulie; Sazan S Abdullah; Elisabeth Paus; Léon Reubsaet; Trine G Halvorsen
Journal:  RSC Adv       Date:  2019-10-29       Impact factor: 4.036

2.  Adsorptive Microtiter Plates As Solid Supports in Affinity Purification Workflows.

Authors:  Frank Klont; Marcel Kwiatkowski; Alen Faiz; Thea van den Bosch; Simon D Pouwels; Frank J Dekker; Nick H T Ten Hacken; Péter Horvatovich; Rainer Bischoff
Journal:  J Proteome Res       Date:  2021-10-20       Impact factor: 4.466

3.  Sample Preparation Strategies for Antibody-Free Quantitative Analysis of High Mobility Group Box 1 Protein.

Authors:  Ingeborg Kvivik; Grete Jonsson; Roald Omdal; Cato Brede
Journal:  Pharmaceuticals (Basel)       Date:  2021-06-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.