BACKGROUND: Portal hypertension is necessary for the development of most clinical complications of cirrhosis. We recently reported a novel, endoscopic ultrasound (EUS)-guided technique for direct portal pressure measurements using a digital pressure wire. AIMS: The aims of this study were to (1) evaluate safety in an animal survival model and (2) compare direct portal vein (PV) versus transhepatic access of a first-order venule.
MATERIALS AND METHODS: Yorkshire pigs, weighing 40-55 kg. Procedures were performed under general anesthesia. PV was identified using a linear array echoendoscope and accessed with a 22-G fine needle aspiration needle preloaded with a digital pressure wire. Access was confirmed by portal venography. Mean digital pressure measurements were recorded over 30 seconds, and again after accessing a first-order portal venule in a transhepatic manner. Procedure times and video logs were maintained throughout. Animals were survived for 2 weeks. Repeat portal pressure measurements were performed before euthanasia and necropsy.
RESULTS: EUS-guided portal pressure measurements ranged from 3 to 11 mm Hg (mean 6.1) and were performed in a mean time of 214 seconds. There was no difference in measurement between the PV and first-order venule, or between baseline and 2-week follow-up. Five of 5 animals survived without incident. On necropsy, there was no evidence of thrombus or hemorrhage.
CONCLUSIONS: This study represents the first survival study after EUS-guided direct portal pressure measurements using a digital pressure wire. This method appears safe, straightforward, and precise. Measurements of the PV and a first-order portal venule appear equivalent, and serial measurement seems feasible.

Entities:  

Keywords:  chronic liver disease; endoscopic ultrasound; hepatic venous pressure gradient; portal hypertension; portal pressure

Mesh:

Year:  2017        PMID: 28445104     DOI: 10.1089/lap.2017.0032

Source DB:  PubMed          Journal:  J Laparoendosc Adv Surg Tech A        ISSN: 1092-6429            Impact factor:   1.878


  4 in total

Review 1.  The Role of EUS in Liver Biopsy.

Authors:  Shaffer R S Mok; David L Diehl
Journal:  Curr Gastroenterol Rep       Date:  2019-01-31

2.  Endoscopic Ultrasound-Guided Portal Pressure Measurement and Interventions.

Authors:  Jason B Samarasena; Kenneth J Chang
Journal:  Clin Endosc       Date:  2018-05-31

Review 3.  EUS-guided portal pressure measurement (with videos).

Authors:  Jason B Samarasena; Allen R Yu; Kenneth J Chang
Journal:  Endosc Ultrasound       Date:  2018 Jul-Aug       Impact factor: 5.628

Review 4.  The role of EUS in diagnosis and treatment of liver disorders.

Authors:  Sara Campos; Jan-Werner Poley; Lydi van Driel; Marco J Bruno
Journal:  Endosc Int Open       Date:  2019-10-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.