Sir, Central venous (CV) thrombosis can occur as a complication of head and neck infections, surgery, CV access, local or distant malignancy, and intravenous (IV) drug abuse or spontaneously, among which CV catheterization being the most common etiology.[12] We report a case of undiagnosed bilateral CV thrombosis in a patient with cerebral palsy who presented with respiratory distress in the Intensive Care Unit (ICU). An 18-year-old male patient with cerebral palsy was admitted in the ICU with history of dyspnea. His respiratory rate was 34 breaths/min, saturation was 85% on room air, and bilateral wheezes were present. Chest X-ray revealed heterogeneous opacity in the right lower zone. A provisional diagnosis of community-acquired pneumonia was made, for which IV antibiotic therapy was to be given. The patient had history of seizure episodes 3–4 times a day since early childhood, for which he was taking multiple oral antiepileptics. During seizures exacerbation, IV antiepileptic drugs were to be administered, for which he required repeated IV cannulation and many a times even CV cannulation. Initially, the CV access was obtained easily, but each subsequent attempt of cannulation took more time, and over the period of time, the vein get punctured but guide wire could not be negotiated further. In view of difficult peripheral venous access due to the presence of severe contracture in all the four limbs, CV cannulation in the right jugular vein was planned. An ultrasonography (USG) examination (GE Healthcare, USA) was done before attempting cannulation. In short-axis view of ultrasound, the jugular veins were easily identified on both sides, but on tracing it further down in long-axis view showed near total obstruction of lumen due to thrombus and fibrosis [Figure 1]. Ultrasound subclavian veins also revealed the presence of thrombus. Hence, plan to cannulate CV was abandoned, and USG-guided peripheral venous access with 22-gauge 80 mm polyethylene pediatric catheter (Leadercath, Vygon) was obtained in median cubital vein. He remained on IV antibiotics and nebulization therapy for 3 days in ICU, to which he responded well and discharged to home after 5 days.
Figure 1

Visualization of the internal jugular vein under short-axis view of ultrasound and long-axis view of the lower part of the internal jugular vein shows noncompressible, hyperechoic thrombus along with fibrosis

Visualization of the internal jugular vein under short-axis view of ultrasound and long-axis view of the lower part of the internal jugular vein shows noncompressible, hyperechoic thrombus along with fibrosis The conventional approach to CV cannulation based on anatomic surface landmark identification, but it can lead to complications such as multiple attempts, arterial puncture, hematoma, pneumothorax, and even vascular thrombosis. The use of bedside ultrasound not only allows direct visualization of target vessels but also allows the assessment of anatomic variants and presence of vascular thrombosis.[3] Due to the presence of contractures in extremities and thrombosed vessels, attempts at blind peripheral IV access were unsuccessful, so the patient had undergone multiple times CV cannulation for the administration of antiepileptic drugs resulting in thrombosis. Patients with bilateral CV thrombosis may result in neck and limb pain, edema of the head and neck, SVC syndrome, and pulmonary embolism,[4] but this patient was asymptomatic as it was a gradual process which may have resulted in multiple collaterals veins involving external jugular vein. A diagnosis of venous thrombosis by USG in the present case was made by the presence of noncompressible, hyperechoic intravascular mass and the absence of respiratory variation [Figure 1], further confirmation by computed tomography angiography could not be done as the patient's mother did not gave consent for any invasive procedure. This case highlights that a screening USG should be done before attempting CV cannulation in short-axis view as well as in long-axis view to establish the patency of these vessels further down, especially in the patient with history of multiple CV cannulations.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  3 in total

1.  Mechanical complications of central venous catheters.

Authors:  Lewis A Eisen; Mangala Narasimhan; Jeffrey S Berger; Paul H Mayo; Mark J Rosen; Roslyn F Schneider
Journal:  J Intensive Care Med       Date:  2006 Jan-Feb       Impact factor: 3.510

2.  Implantation of 3951 long-term central venous catheters: performances, risk analysis, and patient comfort after ultrasound-guidance introduction.

Authors:  Adriano Peris; Giovanni Zagli; Manuela Bonizzoli; Giovanni Cianchi; Marco Ciapetti; Rosario Spina; Valentina Anichini; Francesco Lapi; Stefano Batacchi
Journal:  Anesth Analg       Date:  2010-09-09       Impact factor: 5.108

3.  Improved results using ultrasound guidance for central venous access.

Authors:  Marcus Gann; Armando Sardi
Journal:  Am Surg       Date:  2003-12       Impact factor: 0.688

  3 in total
  1 in total

1.  Volume change following valsalva: A Valuable tool to be incorporated in the stepwise technique for central venous catheter placement under ultrasound guidance: An opinion.

Authors:  Vijaya P Patil; Sumitra G Bakshi; Harshita Singh
Journal:  Ann Card Anaesth       Date:  2019 Jul-Sep
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.