Literature DB >> 28442856

Functional Outcome of Fixation of Complex Intra-articular Distal Radius Fractures with a Variable-Angle Distal Radius Volar Rim Plate.

M Spiteri1, W Ng1, J Matthews1, D Power1.   

Abstract

Aim To evaluate the outcome of these complex fractures using a volar approach and the DePuy Synthes variable-angle 2.4-mm distal radius rim plate. This plate is precontoured to the volar rim for placement distal to the watershed line allowing purchase of the rim fragment of the lunate facet. Its low profile and smooth edges are designed to minimize flexor tendon irritation. Method We report on a consecutive series of far distal AO-23B3 and AO-23C3 fractures treated using this plate in a tertiary hand center between November 2011 and May 2014. Range of motion, grip strength, and complications were assessed at the final clinical review. Disabilities of the arm, shoulder, and hand (DASH) and patient evaluation measure (PEM) scores were assessed at 12 months after surgery. Results Twenty-six patients were included in this review. Six patients were lost to follow-up at 3 months. This plate was used in isolation in 17 cases, and in combination with a dorsal plate, in cases of dorsal instability after volar plating, in 10 patients. DASH and PEM scores 1 year after surgery were 17.6 and 27%, respectively. Visual analog scores for patient treatment satisfaction and severity of pain showed good satisfaction with treatment and mild intermittent pain on activity. Postoperative range of motion was variable and grip strength was of 71% of the uninjured contralateral side. There were no cases of flexor or extensor tendon rupture. Tendon irritation was noted in two patients. Removal of metal was performed in four patients. Loss of reduction occurred in one case and neurologic complications in two cases. Conclusion This implant is specifically designed for the management of far distal complex intra-articular fractures of the distal radius. Despite the complexity of these fracture patterns and the challenge they pose to accurate reduction and stable fixation, outcomes were satisfactory in this small series. There were no cases of tendon rupture. Removal of metal is not necessary in all cases, but prompt removal should be performed in cases of tendon irritation in view of the risk of tendon rupture.

Entities:  

Keywords:  distal radius fracture; open reduction and internal fixation; patient evaluation measure; variable-angle distal radius rim plate

Year:  2017        PMID: 28442856      PMCID: PMC5403733          DOI: 10.1055/s-0037-1601325

Source DB:  PubMed          Journal:  J Hand Microsurg        ISSN: 0974-3227


  22 in total

1.  [Results of palmar T-plate osteosynthesis in unstable fractures of the distal radius].

Authors:  C Dumont; M Fuchs; E K Folwaczny; C Heuermann; K M Stürmer
Journal:  Chirurg       Date:  2003-09       Impact factor: 0.955

2.  Fractures of the dorsal articular margin of the distal part of the radius with dorsal radiocarpal subluxation.

Authors:  Santiago A Lozano-Calderón; Job Doornberg; David Ring
Journal:  J Bone Joint Surg Am       Date:  2006-07       Impact factor: 5.284

3.  Operative management of distal radial fractures with 2.4-millimeter locking plates: a multicenter prospective case series. Surgical technique.

Authors:  Jesse B Jupiter; M Marent-Huber
Journal:  J Bone Joint Surg Am       Date:  2010-03       Impact factor: 5.284

4.  [Palmar fixed angle plating systems for instable distal radius fractures].

Authors:  H Krimmer; C Pessenlehner; K Hasselbacher; M Meier; F Roth; R Meier
Journal:  Unfallchirurg       Date:  2004-06       Impact factor: 1.000

5.  Volar fixed-angle plate fixation for unstable distal radius fractures in the elderly patient.

Authors:  Jorge L Orbay; Diego L Fernandez
Journal:  J Hand Surg Am       Date:  2004-01       Impact factor: 2.230

6.  The internal consistency and validity of the Patient Evaluation Measure for outcomes assessment in distal radius fractures.

Authors:  D P Forward; J S Sithole; T R C Davis
Journal:  J Hand Surg Eur Vol       Date:  2007-06

7.  Complications following dorsal versus volar plate fixation of distal radius fracture: a meta-analysis.

Authors:  Jie Wei; Tu-Bao Yang; Wei Luo; Jia-Bi Qin; Fan-Jing Kong
Journal:  J Int Med Res       Date:  2013-02-07       Impact factor: 1.671

8.  Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial.

Authors:  Alexia Karantana; Nicholas D Downing; Daren P Forward; Mark Hatton; Andrew M Taylor; Brigitte E Scammell; Chris G Moran; Tim R C Davis
Journal:  J Bone Joint Surg Am       Date:  2013-10-02       Impact factor: 5.284

9.  Complications associated with operative versus nonsurgical treatment of distal radius fractures in patients aged 65 years and older.

Authors:  Kristina Lutz; Kwan M Yeoh; Joy C MacDermid; Caitlin Symonette; Ruby Grewal
Journal:  J Hand Surg Am       Date:  2014-06-02       Impact factor: 2.230

10.  Type C distal radial fractures treated with conventional AO plates: an easy and cost-saving solution in a locking plate era.

Authors:  Bas Twigt; Michael Bemelman; Koen Lansink; Loek Leenen
Journal:  Int Orthop       Date:  2013-01-11       Impact factor: 3.075

View more
  2 in total

1.  Functional outcomes following fixation of a marginal distal radius fracture with two commonly used volar locking plates: a retrospective cohort study.

Authors:  Yin-Ming Huang; Chun-Yu Chen; Kai-Cheng Lin; Yih-Wen Tarng; Ching-Yi Liao; Wei-Ning Chang
Journal:  BMC Musculoskelet Disord       Date:  2022-01-03       Impact factor: 2.362

2.  Early hybrid nonbridging external fixation of unstable distal radius fractures in patients aged ≥50 years.

Authors:  Pengfei Cheng; Fan Wu; Hua Chen; Chaoyin Jiang; Ting Wang; Pei Han; Yimin Chai
Journal:  J Int Med Res       Date:  2019-12-23       Impact factor: 1.671

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.