A purpose-built neck coil for black-blood DANTE-prepared carotid artery imaging at 7T.

Konstantinos Papoutsis1, Linqing Li2, Jamie Near3, Stephen Payne4, Peter Jezzard5.   

Abstract

Atherosclerotic plaques in the bifurcation of the carotid arteries can pose a significant health risk due to possible plaque rupture and subsequent stroke. The assessment of plaques, and evaluation of the risk they pose, can be performed with Black-Blood (BB) vessel wall magnetic resonance imaging. However, resolution at standard clinical field strengths (up to 3T) is limited, hampering reliable assessment and diagnosis. The aim of this study was to investigate the benefits of 7T MRI using a BB application that has been successful at clinical field strengths. Therefore, for BB imaging, each sequence was preceded with 'Delay Alternating with Nutation for Tailored Excitation' (DANTE) preparation pulses for blood signal suppression. A coil comprising a 4-channel Tx array was designed and built to provide the required excitation coverage for the DANTE train; and a 4-channel Rx array was constructed to target the carotid bifurcation. Human and phantom results showed satisfactory blood suppression and comparable SNR and CNR to 3T, therefore demonstrating the feasibility of the application at 7T. However, the imposed SAR restrictions led to long scan times and subsequent motion artifacts. Thus, more accurate local SAR supervision schemes are required which could lead to a further improvement of BB DANTE vessel wall imaging at 7T.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  7Tesla; Neck imaging; Radiofrequency coil; Ultra-high field

Mesh:

Year:  2017        PMID: 28438710     DOI: 10.1016/j.mri.2017.04.011

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Bilateral Multiband 4D Flow MRI of the Carotid Arteries at 7T.

Authors:  Sebastian Schmitter; Gregor Adriany; Matt Waks; Steen Moeller; Maria Aristova; Alireza Vali; Edward J Auerbach; Pierre-François Van de Moortele; Kamil Ugurbil; Susanne Schnell
Journal:  Magn Reson Med       Date:  2020-03-18       Impact factor: 4.668

2.  A flexible five-channel shielded-coaxial-cable (SCC) transceive neck coil for high-resolution carotid imaging at 7T.

Authors:  Thomas Ruytenberg; Andrew Webb; Irena Zivkovic
Journal:  Magn Reson Med       Date:  2020-02-12       Impact factor: 4.668

3.  Ultra-high resolution, 3-dimensional magnetic resonance imaging of the atherosclerotic vessel wall at clinical 7T.

Authors:  Martin J Willemink; Bram F Coolen; Hadrien Dyvorne; Philip M Robson; Ilda Bander; Seigo Ishino; Alison Pruzan; Arthi Sridhar; Bei Zhang; Priti Balchandani; Venkatesh Mani; Gustav J Strijkers; Aart J Nederveen; Tim Leiner; Zahi A Fayad; Willem J M Mulder; Claudia Calcagno
Journal:  PLoS One       Date:  2020-12-14       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.