Literature DB >> 28437194

Comparison of Three Final Irrigation Activation Techniques: Effects on Canal Cleanness, Smear Layer Removal, and Dentinal Tubule Penetration of Two Root Canal Sealers.

Elmas Turkel1, Emel Olga Onay2, Mete Ungor3.   

Abstract

OBJECTIVE: The aim of this study was to compare three final irrigation activation techniques with respect to their effects on debridement efficacy, smear layer removal, and dentinal tubule penetration of two different root canal sealers. BACKGROUND DATA: Different applications to improve the delivery of irrigating solutions within the root canal system are currently being investigated, as not all of the mechanisms and effects of these techniques have been clearly identified.
MATERIALS AND METHODS: One hundred forty-two single-rooted teeth were randomly divided into a control group and three experimental groups based on the irrigant activation technique used: EndoVac (EV) system, photon-induced photoacoustic streaming (PIPS), and conventional syringe irrigation (CSI). Thirteen specimens from each experimental group were evaluated for debris and smear layer removal using scanning electron microscopy. The remaining 30 specimens per group were divided into two subgroups according to the root canal sealer used: AH Plus and TotalFill BC. The maximum depth and total percentage of sealer penetration were measured using confocal laser scanning microscopy.
RESULTS: PIPS resulted in significantly less debris in the middle third of the root canal compared with CSI (p < 0.01). There were no significant differences among CSI, EV, and PIPS concerning debris removal at coronal and apical levels or smear layer removal at all levels (p > 0.05). TotalFill BC use after final irrigation with EV and CSI at 2 mm or PIPS at 5 mm exhibited a significantly higher percentage of sealer penetration than that with AH Plus (p < 0.05). When AH Plus was used, PIPS allowed deeper sealer penetration than CSI at 2 mm (p < 0.05).
CONCLUSIONS: The effects of EV, PIPS, and CSI on debridement efficacy, smear layer removal, and dentinal tubule penetration were almost comparable. TotalFill BC showed superior tubular penetration than AH Plus.

Entities:  

Keywords:  Er:YAG; dentin; dentistry; endodontics; laser confocal microscopy; lasers

Mesh:

Substances:

Year:  2017        PMID: 28437194     DOI: 10.1089/pho.2016.4234

Source DB:  PubMed          Journal:  Photomed Laser Surg        ISSN: 1549-5418            Impact factor:   2.796


  3 in total

1.  Efficacy of Photoinduced Photoacoustic Streaming and Diode Laser Irrigation Techniques on Smear Layer Removal, Sealer Penetration and Push-out Bond Strength.

Authors:  Latifa Mohamed Abdelgawad; Nancy Attia Ahmed ElShafei; Somaia Abdlatif Eissa; Dalia Yahia Ibrahim
Journal:  J Lasers Med Sci       Date:  2022-03-18

2.  Influence of the EndoActivator Irrigation System on Dentinal Tubule Penetration of a Novel Tricalcium Silicate-Based Sealer.

Authors:  Roula El Hachem; Guy Le Brun; Bernard Le Jeune; Fabrice Pellen; Issam Khalil; Marie Abboud
Journal:  Dent J (Basel)       Date:  2018-09-03

3.  Intratubular penetration capacity of HiFlow bioceramic sealer used with warm obturation techniques and single cone: A confocal laser scanning microscopic study.

Authors:  Alberto Casino Alegre; Susana Aranda Verdú; José Ignacio Zarzosa López; Eliseo Plasencia Alcina; Jorge Rubio Climent; Antonio Pallarés Sabater
Journal:  Heliyon       Date:  2022-08-27
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.