Literature DB >> 28436852

Frequency-Selective Computed Tomography: Applications During Periodic Thoracic Motion.

Jacob Herrmann, Eric A Hoffman, David W Kaczka.   

Abstract

We seek to use computed tomography (CT) to characterize regional lung parenchymal deformation during high-frequency and multi-frequency oscillatory ventilation. Periodic motion of thoracic structures results in artifacts of CT images obtained by standard reconstruction algorithms, especially for frequencies exceeding that of the X-ray source rotation. In this paper, we propose an acquisition and reconstruction technique for high-resolution imaging of the thorax during periodic motion. Our technique relies on phase-binning projections according to the frequency of subject motion relative to the scanner rotation, prior to volumetric reconstruction. The mathematical theory and limitations of the proposed technique are presented, and then validated in a simulated phantom as well as a living porcine subject during oscillatory ventilation. The 4-D image sequences obtained using this frequency-selective reconstruction technique yielded high-spatio-temporal resolution of the thorax during periodic motion. We conclude that the frequency-based selection of CT projections is ideal for characterizing dynamic deformations of thoracic structures that are ordinarily obscured by motion artifact using conventional reconstruction techniques.

Entities:  

Mesh:

Year:  2017        PMID: 28436852      PMCID: PMC5639881          DOI: 10.1109/TMI.2017.2694887

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  46 in total

1.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

2.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry.

Authors:  Gary E Christensen; Joo Hyun Song; Wei Lu; Issam El Naqa; Daniel A Low
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

3.  Cardiac motion correction based on partial angle reconstructed images in x-ray CT.

Authors:  Seungeon Kim; Yongjin Chang; Jong Beom Ra
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

4.  Analysis of regional mechanics in canine lung injury using forced oscillations and 3D image registration.

Authors:  David W Kaczka; Kunlin Cao; Gary E Christensen; Jason H T Bates; Brett A Simon
Journal:  Ann Biomed Eng       Date:  2010-12-04       Impact factor: 3.934

5.  Multifrequency Oscillatory Ventilation in the Premature Lung: Effects on Gas Exchange, Mechanics, and Ventilation Distribution.

Authors:  David W Kaczka; Jacob Herrmann; C Elroy Zonneveld; David G Tingay; Anna Lavizzari; Peter B Noble; J Jane Pillow
Journal:  Anesthesiology       Date:  2015-12       Impact factor: 7.892

6.  Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

Authors:  M Kachelriess; W A Kalender
Journal:  Med Phys       Date:  1998-12       Impact factor: 4.071

7.  Volumetric xenon-CT imaging of conventional and high-frequency oscillatory ventilation.

Authors:  Daniel G Mulreany; Brett A Simon; Kieran J Murphy; R Blaine Easley
Journal:  Acad Radiol       Date:  2009-03-05       Impact factor: 3.173

8.  A fully four-dimensional, iterative motion estimation and compensation method for cardiac CT.

Authors:  Qiulin Tang; Jochen Cammin; Somesh Srivastava; Katsuyuki Taguchi
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

Review 9.  Technical principles of dual source CT.

Authors:  Martin Petersilka; Herbert Bruder; Bernhard Krauss; Karl Stierstorfer; Thomas G Flohr
Journal:  Eur J Radiol       Date:  2008-10-07       Impact factor: 3.528

Review 10.  Advances in 4D medical imaging and 4D radiation therapy.

Authors:  G Li; D Citrin; K Camphausen; B Mueller; C Burman; B Mychalczak; R W Miller; Y Song
Journal:  Technol Cancer Res Treat       Date:  2008-02
View more
  7 in total

1.  Multi-resolution convolutional neural networks for fully automated segmentation of acutely injured lungs in multiple species.

Authors:  Sarah E Gerard; Jacob Herrmann; David W Kaczka; Guido Musch; Ana Fernandez-Bustamante; Joseph M Reinhardt
Journal:  Med Image Anal       Date:  2019-11-07       Impact factor: 8.545

Review 2.  Assessment of Heterogeneity in Lung Structure and Function During Mechanical Ventilation: A Review of Methodologies.

Authors:  Jacob Herrmann; Michaela Kollisch-Singule; Joshua Satalin; Gary F Nieman; David W Kaczka
Journal:  J Eng Sci Med Diagn Ther       Date:  2022-05-11

3.  Effects of Lung Injury on Regional Aeration and Expiratory Time Constants: Insights From Four-Dimensional Computed Tomography Image Registration.

Authors:  Jacob Herrmann; Sarah E Gerard; Wei Shao; Yi Xin; Maurizio Cereda; Joseph M Reinhardt; Gary E Christensen; Eric A Hoffman; David W Kaczka
Journal:  Front Physiol       Date:  2021-07-28       Impact factor: 4.755

Review 4.  Imaging the Injured Lung: Mechanisms of Action and Clinical Use.

Authors:  Maurizio Cereda; Yi Xin; Alberto Goffi; Jacob Herrmann; David W Kaczka; Brian P Kavanagh; Gaetano Perchiazzi; Takeshi Yoshida; Rahim R Rizi
Journal:  Anesthesiology       Date:  2019-09       Impact factor: 7.892

5.  Regional Gas Transport During Conventional and Oscillatory Ventilation Assessed by Xenon-Enhanced Computed Tomography.

Authors:  Jacob Herrmann; Sarah E Gerard; Joseph M Reinhardt; Eric A Hoffman; David W Kaczka
Journal:  Ann Biomed Eng       Date:  2021-05-04       Impact factor: 4.219

6.  Parenchymal strain heterogeneity during oscillatory ventilation: why two frequencies are better than one.

Authors:  Jacob Herrmann; Merryn H Tawhai; David W Kaczka
Journal:  J Appl Physiol (1985)       Date:  2017-10-19

7.  Quantifying Regional Lung Deformation Using Four-Dimensional Computed Tomography: A Comparison of Conventional and Oscillatory Ventilation.

Authors:  Jacob Herrmann; Sarah E Gerard; Wei Shao; Monica L Hawley; Joseph M Reinhardt; Gary E Christensen; Eric A Hoffman; David W Kaczka
Journal:  Front Physiol       Date:  2020-02-20       Impact factor: 4.566

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.