Chan Park1, Seung-Hwan Yoo1, Sang-Won Park1, Kwi-Dug Yun1, Min-Kyung Ji1, Jin-Ho Shin1, Hyun-Pil Lim1.
Abstract
PURPOSE: To investigate the effect of non-thermal atmospheric pressure plasma (NTAPP) treatment on shear bond strength (SBS) between resin cement and colored zirconia made with metal chlorides.Entities:
Keywords: Colored zirconia; Non-thermal atmospheric pressure plasma (NTAPP); Shear bond strength (SBS)
Year: 2017 PMID: 28435621 PMCID: PMC5397588 DOI: 10.4047/jap.2017.9.2.118
Source DB: PubMed Journal: J Adv Prosthodont ISSN: 2005-7806 Impact factor: 1.904
Experimental groups
| Group (N = 10) | Coloring liquid | NTAPP |
|---|---|---|
| N | None | No |
| C | 0.1 wt% aqueous chromium chloride solution | No |
| M | 0.1 wt% aqueous molybdenum chloride solution | No |
| NP | None | Yes |
| CP | 0.1 wt% aqueous chromium chloride solution | Yes |
| MP | 0.1 wt% aqueous molybdenum chloride solution | Yes |
Fig. 1Experimental groups. (A) Uncolored zirconia, (B) 0.1 wt% chromium coloring liquid, (C) 0.1 wt% molybdenum coloring liquid.
NTAPP parameters and condition
| Parameter | Condition |
|---|---|
| Radio frequency (MHz) | 900 |
| Treatment distance (mm) | 5 |
| Power (W) | 300 |
| Treatment time (Sec) | 30 |
| Pressure (Torr) | 760 |
| Plasma density (/cm3) | 1.11 × 1015 |
Fig. 2Process of shear bond strength test. (A) Composite resin cylinder cemented on zirconia disc, (B) Universal testing machine.
Two-way ANOVA test results of effects between subjects
| Source | Sum of squares | df | Mean square | F | Significance |
|---|---|---|---|---|---|
| NTAPP | 69.553 | 1 | 69.553 | 254.014 | < .001* |
| Type of specimen | 19.407 | 2 | 9.704 | 35.438 | < .001* |
| NTAPP × Type of specimen | 0.058 | 2 | 0.029 | 0.107 | .899 |
(*: Significant at P < .05)
Fig. 3Result of Tukey HSD test for shear bond strength before plasma treatment (*: significant at P < .05, **: significant at P < .001).
Fig. 4Result of Tukey HSD test for shear bond strength after plasma treatment (*: significant at P < .05).
Fig. 5Result of Independent t-test for shear bond strength (**: significant at P < .001).
Fig. 6SEM representative image of specimen fractured surfaces (×180 magnification). (A) Non-colored, (B) Non-colored with plasma, (C) Chromium colored, (D) Chromium colored with plasma, (E) Molybdenum colored, (F) Molybdenum colored with plasma (R is composite resin, Z is zirconia specimen).