| Literature DB >> 28435578 |
Abstract
The treatment of fractures in osteopetrosis can be complicated and difficult. We describe the use of an industrial grade tungsten carbide drill bit in the treatment of one of these complex fractures. An industrial grade tungsten carbide drill bit was used to fashion a medullary canal in the surgical treatment of a left peri-implant fracture of the neck of femur in a patient with osteopetrosis. The patient was successfully treated with a hemiarthroplasty with good functional outcomes. A tungsten carbide drill bit serves as an effective and safe option in the treatment of osteopetrotic femoral neck fractures.Entities:
Keywords: neck of femur fracture; osteopetrosis; tungsten carbide
Year: 2017 PMID: 28435578 PMCID: PMC5393118 DOI: 10.5704/MOJ.1703.007
Source DB: PubMed Journal: Malays Orthop J ISSN: 1985-2533
Fig. 1(a) Pre and post-operative radiographs following the fall in 2011 and (b) Left neck of femur fracture sustained in 2014.
Fig. 2aComplete obliteration of the femoral canal with evidence of thermal necrosis from the previous surgery.
Fig. 2bCreation of the femoral canal, using the tungsten carbide drill bit with the assistance of intra-operative imaging.
Fig. 2cMedullary canal fashioned using the tungsten carbide drill bit.
Fig. 3Radiograph 2 years post-operative.