Complete Eradication of Biofilm From Orthopedic Materials.

Jeffrey T Leary1, Matthew M Werger1, William H Broach2, Lindsey N Shaw2, Brandon G Santoni3, Thomas L Bernasek1, Steven T Lyons1.   

Abstract

BACKGROUND: Interest exists in finding alternatives to current management strategies in periprosthetic joint infections, which typically include a 2-stage revision with placement of an antibiotic spacer and delayed placement of a new implant. We studied the efficacy of autoclaving, ultrasonication, and mechanical scrubbing for sterilization and biofilm eradication on infected cobalt-chrome discs.
METHODS: Strains of Staphylococcus aureus MRSA252 or Staphylococcus epidermidis RP62A were grown on the discs. For each strain, discs were divided into 5 groups (5 discs each) and exposed to several sterilization and biofilm eradication treatments: (1) autoclave, (2) autoclave + sonication, (3) autoclave + saline scrub, (4) autoclave + 4% chlorhexidine (CHC) scrub, and (5) autoclave + sonication + CHC scrub. Sterilization and biofilm eradication were quantified with crystal violet assays and scanning electron microscopy.
RESULTS: Relative to nontreated controls, autoclaving alone reduced biofilm load by 33.9% and 54.7% for MRSA252 and RP62A strains, respectively. Biofilm removal was maximized with the combined treatment of autoclaving and CHC scrub for MRSA252 (100%) and RP62A (99.5%). The addition of sonication between autoclaving and CHC scrubbing resulted in no statistically significant improvement in biofilm removal. High-resolution scanning electron microscopy revealed no cells or biofilm for this combined treatment.
CONCLUSION: Using 2 commonly encountered bacterial strains in periprosthetic joint infection, infected cobalt-chrome discs were sterilized and eradicated of residual biofilm with a combination of autoclaving and CHC scrubbing.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  biofilm; infected total knee arthroplasty; mechanical scrubbing; steam sterilization; ultrasonication

Mesh:

Substances:

Year:  2017        PMID: 28434696     DOI: 10.1016/j.arth.2017.03.050

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  High bacterial contamination rate of electrocautery tips during total hip and knee arthroplasty.

Authors:  Hussein Abdelaziz; Akos Zahar; Christian Lausmann; Thorsten Gehrke; Helmut Fickenscher; Eduardo M Suero; Matthias Gebauer; Mustafa Citak
Journal:  Int Orthop       Date:  2018-02-12       Impact factor: 3.075

Review 2.  Staphylococcus aureus Evasion of Host Immunity in the Setting of Prosthetic Joint Infection: Biofilm and Beyond.

Authors:  Benjamin F Ricciardi; Gowrishankar Muthukrishnan; Elysia Masters; Mark Ninomiya; Charles C Lee; Edward M Schwarz
Journal:  Curr Rev Musculoskelet Med       Date:  2018-09

Review 3.  Microbial biofilm: formation, architecture, antibiotic resistance, and control strategies.

Authors:  Muzamil Ahmad Rather; Kuldeep Gupta; Manabendra Mandal
Journal:  Braz J Microbiol       Date:  2021-09-23       Impact factor: 2.214

4.  A New Bioactive Compound From the Marine Sponge-Derived Streptomyces sp. SBT348 Inhibits Staphylococcal Growth and Biofilm Formation.

Authors:  Srikkanth Balasubramanian; Joseph Skaf; Ulrike Holzgrabe; Richa Bharti; Konrad U Förstner; Wilma Ziebuhr; Ute H Humeida; Usama R Abdelmohsen; Tobias A Oelschlaeger
Journal:  Front Microbiol       Date:  2018-07-11       Impact factor: 5.640

5.  A Mid-term Follow-up Study on the Reimplantation of Autoclaved Femoral and Tibial Components as Spacers for Treating Infected Total Knee Arthroplasty.

Authors:  Peng Li; Zhiqi Zhu; Xiangyang Tang; Zhanjun Shi
Journal:  Orthop Surg       Date:  2022-07-27       Impact factor: 2.279

6.  Highly variable effect of sonication to dislodge biofilm-embedded Staphylococcus epidermidis directly quantified by epifluorescence microscopy: an in vitro model study.

Authors:  Erik T Sandbakken; Eivind Witsø; Bjørnar Sporsheim; Kjartan W Egeberg; Olav A Foss; Linh Hoang; Geir Bjerkan; Kirsti Løseth; Kåre Bergh
Journal:  J Orthop Surg Res       Date:  2020-11-11       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.