Julia Fiona-Maree Gilmartin-Thomas1, Felicity Smith2, Rory Wolfe3, Yogini Jani4. 1. Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Melbourne, Australia; Research Department of Practice and Policy, University College London School of Pharmacy, London, United Kingdom. Electronic address: julia.gilmartin-thomas@monash.edu. 2. Research Department of Practice and Policy, University College London School of Pharmacy, London, United Kingdom. 3. Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine, Monash University, Melbourne, Australia. 4. Research Department of Practice and Policy, University College London School of Pharmacy, London, United Kingdom; Pharmacy Department, University College London Hospitals NHS Foundation Trust, London, United Kingdom.
Abstract
BACKGROUND: No published study has been specifically designed to compare medication administration errors between original medication packaging and multi-compartment compliance aids in care homes, using direct observation. OBJECTIVES: Compare the effect of original medication packaging and multi-compartment compliance aids on medication administration accuracy. DESIGN: Prospective observational. SETTING: Ten Greater London care homes. PARTICIPANTS: Nurses and carers administering medications. METHODS: Between October 2014 and June 2015, a pharmacist researcher directly observed solid, orally administered medications in tablet or capsule form at ten purposively sampled care homes (five only used original medication packaging and five used both multi-compartment compliance aids and original medication packaging). The medication administration error rate was calculated as the number of observed doses administered (or omitted) in error according to medication administration records, compared to the opportunities for error (total number of observed doses plus omitted doses). RESULTS: Over 108.4h, 41 different staff (35 nurses, 6 carers) were observed to administer medications to 823 residents during 90 medication administration rounds. A total of 2452 medication doses were observed (1385 from original medication packaging, 1067 from multi-compartment compliance aids). One hundred and seventy eight medication administration errors were identified from 2493 opportunities for error (7.1% overall medication administration error rate). A greater medication administration error rate was seen for original medication packaging than multi-compartment compliance aids (9.3% and 3.1% respectively, risk ratio (RR)=3.9, 95% confidence interval (CI) 2.4 to 6.1, p<0.001). Similar differences existed when comparing medication administration error rates between original medication packaging (from original medication packaging-only care homes) and multi-compartment compliance aids (RR=2.3, 95%CI 1.1 to 4.9, p=0.03), and between original medication packaging and multi-compartment compliance aids within care homes that used a combination of both medication administration systems (RR=4.3, 95%CI 2.7 to 6.8, p<0.001). A significant difference in error rate was not observed between use of a single or combination medication administration system (p=0.44). CONCLUSION: The significant difference in, and high overall, medication administration error rate between original medication packaging and multi-compartment compliance aids supports the use of the latter in care homes, as well as local investigation of tablet and capsule impact on medication administration errors and staff training to prevent errors occurring. As a significant difference in error rate was not observed between use of a single or combination medication administration system, common practice of using both multi-compartment compliance aids (for most medications) and original packaging (for medications with stability issues) is supported.
BACKGROUND: No published study has been specifically designed to compare medication administration errors between original medication packaging and multi-compartment compliance aids in care homes, using direct observation. OBJECTIVES: Compare the effect of original medication packaging and multi-compartment compliance aids on medication administration accuracy. DESIGN: Prospective observational. SETTING: Ten Greater London care homes. PARTICIPANTS: Nurses and carers administering medications. METHODS: Between October 2014 and June 2015, a pharmacist researcher directly observed solid, orally administered medications in tablet or capsule form at ten purposively sampled care homes (five only used original medication packaging and five used both multi-compartment compliance aids and original medication packaging). The medication administration error rate was calculated as the number of observed doses administered (or omitted) in error according to medication administration records, compared to the opportunities for error (total number of observed doses plus omitted doses). RESULTS: Over 108.4h, 41 different staff (35 nurses, 6 carers) were observed to administer medications to 823 residents during 90 medication administration rounds. A total of 2452 medication doses were observed (1385 from original medication packaging, 1067 from multi-compartment compliance aids). One hundred and seventy eight medication administration errors were identified from 2493 opportunities for error (7.1% overall medication administration error rate). A greater medication administration error rate was seen for original medication packaging than multi-compartment compliance aids (9.3% and 3.1% respectively, risk ratio (RR)=3.9, 95% confidence interval (CI) 2.4 to 6.1, p<0.001). Similar differences existed when comparing medication administration error rates between original medication packaging (from original medication packaging-only care homes) and multi-compartment compliance aids (RR=2.3, 95%CI 1.1 to 4.9, p=0.03), and between original medication packaging and multi-compartment compliance aids within care homes that used a combination of both medication administration systems (RR=4.3, 95%CI 2.7 to 6.8, p<0.001). A significant difference in error rate was not observed between use of a single or combination medication administration system (p=0.44). CONCLUSION: The significant difference in, and high overall, medication administration error rate between original medication packaging and multi-compartment compliance aids supports the use of the latter in care homes, as well as local investigation of tablet and capsule impact on medication administration errors and staff training to prevent errors occurring. As a significant difference in error rate was not observed between use of a single or combination medication administration system, common practice of using both multi-compartment compliance aids (for most medications) and original packaging (for medications with stability issues) is supported.
Authors: Diana A van Riet-Nales; Katarina Sundberg; Anthonius de Boer; Blanka Hirschlérova Journal: Br J Clin Pharmacol Date: 2020-10 Impact factor: 4.335
Authors: Julia F-M Gilmartin-Thomas; Andrew Forbes; Danny Liew; John J McNeil; Flavia M Cicuttini; Alice J Owen; Michael E Ernst; Mark R Nelson; Jessica Lockery; Stephanie A Ward; Ljoudmila Busija Journal: Pain Pract Date: 2021-01-21 Impact factor: 3.183
Authors: Esa Yh Chen; J Simon Bell; Jenni Ilomaki; Claire Keen; Megan Corlis; Michelle Hogan; Jan Van Emden; Sarah N Hilmer; Janet K Sluggett Journal: Clin Interv Aging Date: 2019-10-22 Impact factor: 4.458
Authors: Nicolas Dugré; J Simon Bell; Ria E Hopkins; Jenni Ilomäki; Esa Y H Chen; Megan Corlis; Jan Van Emden; Michelle Hogan; Janet K Sluggett Journal: J Clin Med Date: 2021-03-06 Impact factor: 4.241