Difference optimization: Automatic correction of relative frequency and phase for mean non-edited and edited GABA 1H MEGA-PRESS spectra.

Marianne Cleve1, Martin Krämer2, Alexander Gussew3, Jürgen R Reichenbach4.   

Abstract

Phase and frequency corrections of magnetic resonance spectroscopic data are of major importance to obtain reliable and unambiguous metabolite estimates as validated in recent research for single-shot scans with the same spectral fingerprint. However, when using the J-difference editing technique 1H MEGA-PRESS, misalignment between mean edited (ON‾) and non-edited (OFF‾) spectra that may remain even after correction of the corresponding individual single-shot scans results in subtraction artefacts compromising reliable GABA quantitation. We present a fully automatic routine that iteratively optimizes simultaneously relative frequencies and phases between the mean ON‾ and OFF‾1H MEGA-PRESS spectra while minimizing the sum of the magnitude of the difference spectrum (L1 norm). The proposed method was applied to simulated spectra at different SNR levels with deliberately preset frequency and phase errors. Difference optimization proved to be more sensitive to small signal fluctuations, as e.g. arising from subtraction artefacts, and outperformed the alternative spectral registration approach, that, in contrast to our proposed linear approach, uses a nonlinear least squares minimization (L2 norm), at all investigated levels of SNR. Moreover, the proposed method was applied to 47 MEGA-PRESS datasets acquired in vivo at 3T. The results of the alignment between the mean OFF‾ and ON‾ spectra were compared by applying (a) no correction, (b) difference optimization or (c) spectral registration. Since the true frequency and phase errors are not known for in vivo data, manually corrected spectra were used as the gold standard reference (d). Automatically corrected data applying both, method (b) or method (c), showed distinct improvements of spectra quality as revealed by the mean Pearson correlation coefficient between corresponding real part mean DIFF‾ spectra of Rbd=0.997±0.003 (method (b) vs. (d)), compared to Rad=0.764±0.220 (method (a) vs. (d)) with no alignment between OFF‾ and ON‾. Method (c) revealed a slightly lower correlation coefficient of Rcd=0.972±0.028 compared to Rbd, that can be ascribed to small remaining subtraction artefacts in the final DIFF‾ spectrum. In conclusion, difference optimization performs robustly with no restrictions regarding the input data range or user intervention and represents a complementary tool to optimize the final DIFF‾ spectrum following the mandatory frequency and phase corrections of single ON and OFF scans prior to averaging.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Edited MRS; Frequency alignment; GABA; MEGA-PRESS; Phase alignment; Subtraction artefacts

Mesh:

Substances:

Year:  2017        PMID: 28431306     DOI: 10.1016/j.jmr.2017.04.004

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  5 in total

1.  In vivo spectral editing of phosphorylethanolamine.

Authors:  Steve C N Hui; Helge J Zöllner; Georg Oeltzschner; Richard A E Edden; Muhammad G Saleh
Journal:  Magn Reson Med       Date:  2021-08-19       Impact factor: 4.668

2.  Frequency and phase correction for multiplexed edited MRS of GABA and glutathione.

Authors:  Mark Mikkelsen; Muhammad G Saleh; Jamie Near; Kimberly L Chan; Tao Gong; Ashley D Harris; Georg Oeltzschner; Nicolaas A J Puts; Kim M Cecil; Iain D Wilkinson; Richard A E Edden
Journal:  Magn Reson Med       Date:  2017-12-07       Impact factor: 4.668

3.  Preprocessing, analysis and quantification in single-voxel magnetic resonance spectroscopy: experts' consensus recommendations.

Authors:  Jamie Near; Ashley D Harris; Christoph Juchem; Roland Kreis; Małgorzata Marjańska; Gülin Öz; Johannes Slotboom; Martin Wilson; Charles Gasparovic
Journal:  NMR Biomed       Date:  2020-02-21       Impact factor: 4.044

4.  Frequency and phase correction of J-difference edited MR spectra using deep learning.

Authors:  Sofie Tapper; Mark Mikkelsen; Blake E Dewey; Helge J Zöllner; Steve C N Hui; Georg Oeltzschner; Richard A E Edden
Journal:  Magn Reson Med       Date:  2020-11-18       Impact factor: 4.668

5.  On the reproducibility of hippocampal MEGA-sLASER GABA MRS at 7T using an optimized analysis pipeline.

Authors:  Yannik Völzke; Eberhard D Pracht; Elke Hattingen; Desmond H Y Tse; Tony Stöcker
Journal:  MAGMA       Date:  2020-08-31       Impact factor: 2.310

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.