Literature DB >> 28429515

A device to measure secretion of individual sweat glands for diagnosis of peripheral neuropathy.

Adam J Loavenbruck1, James S Hodges1, Vincenzo Provitera2, Maria Nolano2, Gwen Wendelshafer-Crabb1, William R Kennedy1.   

Abstract

There is a need for quantitative, precise assessment of small fiber peripheral nerve function. We tested a customized camera device and protocol designed to quantify secretions of individual sweat glands (SGs). Testing was performed on 178 healthy controls and 20 neuropathy subjects. Sweating was stimulated on a 2.25 cm2 skin area by iontophoresis of pilocarpine. The camera imaged sweat from 50 to 400 sweat ducts. We calculated secretion rate of individual SGs, total sweat volume, and number of secreting SGs at four body sites. Neuropathy subjects were tested at the two distal sites to demonstrate the device's capability to detect abnormal sudomotor function. Normal ranges were calculated for each body site. Neuropathy subjects had lower sweat rates per SG, lower total sweat, and lower SG density. The normal values decreased with advancing age, were lower in females, and differed between body sites. There was good agreement with repeat testing. The device provides reliable, precise quantitative measures of sweat secretion from single SGs for characterization of sudomotor nerve function in healthy control subjects and in subjects with known peripheral neuropathy. The test combines the capabilities of existing tests of sudomotor function while providing additional capabilities.
© 2017 Peripheral Nerve Society.

Entities:  

Keywords:  autonomic diseases; clinical neurophysiology; diagnostic test assessment; peripheral neuropathy; sweat test

Mesh:

Substances:

Year:  2017        PMID: 28429515     DOI: 10.1111/jns.12212

Source DB:  PubMed          Journal:  J Peripher Nerv Syst        ISSN: 1085-9489            Impact factor:   3.494


  4 in total

1.  Is postural tachycardia syndrome in the head or in the heart? And other updates on recent autonomic research.

Authors:  Mitchell G Miglis; Srikanth Muppidi
Journal:  Clin Auton Res       Date:  2017-05-13       Impact factor: 4.435

Review 2.  Assessment of sudomotor function.

Authors:  Sylvia J Buchmann; Ana Isabel Penzlin; Marie Luise Kubasch; Ben Min-Woo Illigens; Timo Siepmann
Journal:  Clin Auton Res       Date:  2018-05-08       Impact factor: 4.435

3.  High-resolution axon reflex sweat testing for diagnosis of neuropathy.

Authors:  Adam Loavenbruck; Nathan Sit; Vincenzo Provitera; William Kennedy
Journal:  Clin Auton Res       Date:  2018-07-21       Impact factor: 4.435

Review 4.  Assessment of cutaneous axon-reflex responses to evaluate functional integrity of autonomic small nerve fibers.

Authors:  Mido M Hijazi; Sylvia J Buchmann; Annahita Sedghi; Ben M Illigens; Heinz Reichmann; Gabriele Schackert; Timo Siepmann
Journal:  Neurol Sci       Date:  2020-03-03       Impact factor: 3.307

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.