Literature DB >> 28427980

Comparative Study Between Cobalt Chrome and Titanium Alloy Rods for Multilevel Spinal Fusion: Proximal Junctional Kyphosis More Frequently Occurred in Patients Having Cobalt Chrome Rods.

Sanghyun Han1, Seung-Jae Hyun2, Ki-Jeong Kim1, Tae-Ahn Jahng1, Hyun-Jib Kim1.   

Abstract

BACKGROUND: The use of titanium alloy (Ti) rods is frequently associated with rod fracture after spinal fixation. To address this issue, cobalt chrome (CoCr) rods, which are advantageous because of their greater strength and resistance to fatigue relative to Ti rods, have been introduced. The purpose of the present study was to compare radiographic outcomes after the use of Ti versus CoCr rods in a matched cohort of patients undergoing posterior spinal fusion for treatment of spinal instability.
METHODS: We retrospectively reviewed data from patients who had undergone spinal fusion involving more than 3 levels at a single institution between 2004 and 2015. Patients were matched for age, diagnosis, 3-column osteotomy, levels fused, and T score. Fifty patients with Ti rods were identified and appropriately matched to 50 consecutive patients with CoCr rods.
RESULTS: The distributions of age at surgery, sex, diagnosis, 3-column osteotomy, levels fused, number of patients with previous surgical procedures, and T score did not significantly differ between the 2 groups. However, there were significant differences in length of follow-up (CoCr, 25.0 vs. Ti, 28.5 months; P < 0.001), fusion rate (CoCr, 45 [90%] vs. Ti, 33 [66%]; P = 0.004), occurrence of rod breakage (CoCr, 0 vs. T, 8 [16%]; P = 0.006), and junctional kyphosis (CoCr, 24 [46%] vs. Ti, 9 [18%]; P = 0.003).
CONCLUSIONS: Our findings indicate that the use of CoCr rods is effective in ensuring stability of the posterior spinal construct and accomplishment of spinal fusion. Furthermore, our results indicate that junctional kyphosis may occur more frequently in CoCr systems than in Ti systems.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cobalt chrome; Fracture; Junctional kyphosis; Rod; Titanium alloy

Mesh:

Substances:

Year:  2017        PMID: 28427980     DOI: 10.1016/j.wneu.2017.04.031

Source DB:  PubMed          Journal:  World Neurosurg        ISSN: 1878-8750            Impact factor:   2.104


  13 in total

1.  Determinants of the biomechanical and radiological outcome of surgical correction of adolescent idiopathic scoliosis surgery: the role of rod properties and patient characteristics.

Authors:  Fabrizio Giudici; Fabio Galbusera; Antonino Zagra; Hans-Joachim Wilke; Marino Archetti; Laura Scaramuzzo
Journal:  Eur Spine J       Date:  2017-05-23       Impact factor: 3.134

Review 2.  Metallic Implants Used in Lumbar Interbody Fusion.

Authors:  Jakub Litak; Michał Szymoniuk; Wojciech Czyżewski; Zofia Hoffman; Joanna Litak; Leon Sakwa; Piotr Kamieniak
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

3.  Posterior Ligamentous Reinforcement of the Upper Instrumented Vertebrae +1 Does Not Decrease Proximal Junctional Kyphosis in Adult Spinal Deformity.

Authors:  Sravisht Iyer; Francis Lovecchio; Jonathan Charles Elysée; Renaud Lafage; Michael Steinhaus; Frank J Schwab; Virginie Lafage; Han Jo Kim
Journal:  Global Spine J       Date:  2019-08-15

4.  Comparison of Effectiveness between Cobalt Chromium Rods versus Titanium Rods for Treatment of Patients with Spinal Deformity: A Systematic Review and Meta-Analysis.

Authors:  Frank D Shega; HongQi Zhang; Daudi R Manini; MingXing Tang; ShaoHua Liu
Journal:  Adv Orthop       Date:  2020-09-01

Review 5.  Advances in Spinal Fusion Strategies in Adult Deformity Surgery.

Authors:  Jeremy Steinberger; Philip York; Sohrab Virk; Han Jo Kim
Journal:  HSS J       Date:  2020-02-04

Review 6.  Proximal Junctional Kyphosis and Proximal Junctional Failure Following Adult Spinal Deformity Surgery.

Authors:  Seung-Jae Hyun; Byoung Hun Lee; Jong-Hwa Park; Ki-Jeong Kim; Tae-Ahn Jahng; Hyun-Jib Kim
Journal:  Korean J Spine       Date:  2017-12-31

7.  Spinal Deformity Surgery : It Becomes an Essential Part of Neurosurgery.

Authors:  Seung-Jae Hyun; Jong-Myung Jung
Journal:  J Korean Neurosurg Soc       Date:  2018-10-30

8.  Diagonal Trajectory Posterior Screw Instrumentation for Compromised Bone Quality Spine: Groove-Entry Technique/Hooking Screw Hybrid.

Authors:  Ivan Sekiguchi; Naoki Takeda; Naoki Ishida
Journal:  Spine Surg Relat Res       Date:  2018-04-27

9.  Comparison of MRI Visualization Following Minimally Invasive and Open TLIF: A Retrospective Single-Center Study.

Authors:  Vadim A Byvaltsev; Andrei A Kalinin; Morgan B Giers; Valerii V Shepelev; Yurii Ya Pestryakov; Mikhail Yu Biryuchkov
Journal:  Diagnostics (Basel)       Date:  2021-05-19

10.  Choice of Rods in Surgical Treatment of Adolescent Idiopathic Scoliosis: What Are the Clinical Implications of Biomechanical Properties? - A Review of the Literature.

Authors:  Søren Ohrt-Nissen; Benny Dahl; Martin Gehrchen
Journal:  Neurospine       Date:  2018-06-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.