Reliability of pressure waveform analysis to determine correct epidural needle placement in labouring women.

I Al-Aamri1, S H Derzi1, A Moore1, M F Elgueta1, M Moustafa1, T Schricker1, D Q Tran1.   

Abstract

Pressure waveform analysis provides a reliable confirmatory adjunct to the loss-of-resistance technique to identify the epidural space during thoracic epidural anaesthesia, but its role remains controversial in lumbar epidural analgesia during labour. We performed an observational study in 100 labouring women of the sensitivity and specificity of waveform analysis to determine the correct location of the epidural needle. After obtaining loss-of-resistance, the anaesthetist injected 5 ml saline through the epidural needle (accounting for the volume already used in the loss-of-resistance). Sterile extension tubing, connected to a pressure transducer, was attached to the needle. An investigator determined the presence or absence of a pulsatile waveform, synchronised with the heart rate, on a monitor screen that was not in the view of the anaesthetist or the parturient. A bolus of 4 ml lidocaine 2% with adrenaline 5 μg.ml-1 was administered, and the epidural block was assessed after 15 min. Three women displayed no sensory block at 15 min. The results showed: epidural block present, epidural waveform present 93; epidural block absent, epidural waveform absent 2; epidural block present, epidural waveform absent 4; epidural block absent, epidural waveform present 1. Compared with the use of a local anaesthetic bolus to ascertain the epidural space, the sensitivity, specificity, positive and negative predictive values of waveform analysis were 95.9%, 66.7%, 98.9% and 33.3%, respectively. Epidural waveform analysis provides a simple adjunct to loss-of-resistance for confirming needle placement during performance of obstetric epidurals, however, further studies are required before its routine implementation in clinical practice.
© 2017 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Keywords:  complications; epidural analgesia; loss-of-resistance; obstetric; pressure waveform

Mesh:

Year:  2017        PMID: 28419420     DOI: 10.1111/anae.13872

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  [Identification of the epidural space using pressure waveform analysis (CompuFlo® technology): a case series].

Authors:  A Helf; T Schlesinger; N Roewer; P Kranke
Journal:  Anaesthesist       Date:  2019-09-20       Impact factor: 1.041

2.  Efficacy of electrical stimulation on epidural anesthesia for cesarean section: a randomized controlled trial.

Authors:  Young Sung Kim; Hyo Sung Kim; Hyerim Jeong; Chung Hun Lee; Mi Kyoung Lee; Sang Sik Choi
Journal:  BMC Anesthesiol       Date:  2020-06-10       Impact factor: 2.217

3.  Analysis of Epidural Waveform to Determine Correct Epidural Catheter Placement After CSE Labor Analgesia.

Authors:  Alessandra Coccoluto; Giorgio Capogna; Michela Camorcia; Mark Hochman; Matteo Velardo
Journal:  Local Reg Anesth       Date:  2021-06-17