Literature DB >> 28415069

Comparison of Bioimpedance and Underwater Weighing Body Fat Percentage Before and Acutely After Exercise at Varying Intensities.

Brett S Nickerson1, Michael R Esco, Brian M Kliszczewicz, Todd J Freeborn.   

Abstract

Nickerson, BS, Esco, MR, Kliszczewicz, BM, and Freeborn, TJ. Comparison of bioimpedance and underwater weighing body fat percentage before and acutely after exercise at varying intensities. J Strength Cond Res 31(5): 1395-1402, 2017-The purpose of this study was to compare single-frequency bioelectrical impedance analysis (BIA) and bioimpedance spectroscopy (BIS) with underwater weighing (UWW) body fat percentage (BF%) before (PRE), immediately post (IP), and 60 minutes post (60P) an acute bout of moderate and vigorous aerobic exercise. Nine men (age = 24.6 ± 3.7 years) volunteered for this study. Subjects visited the laboratory on 3 separate occasions. Testing included two 30-minute exercise sessions at 60 and 80% heart rate reserve (HRR) and a 30-minute control (CON) trial. The constant error (CE) was significantly higher for BIA at each time point and exercise session (CE = 3.0-4.9% for 60% HRR; 2.5-4.7% for 80% HRR). Conversely, BIS yielded a nonsignificant CE at each time point and exercise session (CE = -0.9 to 1.1% for 60% HRR; -0.3 to 1.2% for 80% HRR). The standard error of estimate (SEE) for both exercise sessions ranged from 2.7 to 3.1% and 3.8-4.3% for BIA and BIS, respectively. The 95% limits of agreement were narrower for BIA (60% HRR = ±5.5 to 7.8%; 80% HRR = ±6.6 to 8.5%) than BIS (60% HRR = ±8.4 to 9.4%; 80% HRR = ±8.1 to 10.2%). Results indicate that BIS can be used for mean group BF% in men at PRE, IP, and 60P time periods. However, BIA yielded a lower SEE and 95% limits of agreement than BIS. Therefore, BIA provides better individual estimates of BF% in men, but the CE should be taken into consideration.

Entities:  

Mesh:

Year:  2017        PMID: 28415069     DOI: 10.1519/JSC.0000000000001716

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  2 in total

1.  Influence of acute consumption of caffeine vs. placebo over Bia-derived measurements of body composition: a randomized, double-blind, crossover design.

Authors:  Cassie M Williamson; Brett S Nickerson; Emily E Bechke; Cherilyn N McLester; Brian M Kliszczewicz
Journal:  J Int Soc Sports Nutr       Date:  2018-02-13       Impact factor: 5.150

2.  Correlation of Subcutaneous Fat Measured on Ultrasound with Body Mass Index.

Authors:  Baby Nadeem; Raham Bacha; Syed Amir Gilani
Journal:  J Med Ultrasound       Date:  2018-12-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.