Literature DB >> 28413521

Efficacy of arsenic trioxide drug-eluting stents in the treatment of coronary heart disease.

Shasha Zhang1, Yuping Zhang1, Shichuan Li1, Zhifeng Li1.   

Abstract

The aim of the current study was to evaluate the safety and clinical efficacy of arsenic trioxide drug-eluting (AVI) stents, manufactured in China, for the treatment of coronary heart disease (CHD). Between January and August 2014, 40 patients with CHD admitted to Yongchuan Hospital with implanted AVI stents alone were selected. A one-year clinical follow-up was completed and one year postoperative coronary angiography was reviewed. Major adverse cardiovascular events (MACE), recurrent angina, stent restenosis and stent thrombosis cases were detected. All 40 patients with CHD completed the one-year clinical follow-up, as well as the one-year postoperative coronary angiography. The follow-up results indicated that the MACE rate was 15.0% (6/40), the target lesion revascularization rate was 15.0% (6/40), the angina recurrence rate was 32.5% (13/40), the in-stent restenosis rate was 20.0% (8/40) and the stent thrombosis rate was zero. There were no cases of cardiac death or nonfatal myocardial infarction. The incidence of restenosis was higher following implantation of the AVI stent and the safety and clinical efficacy were worse than expected.

Entities:  

Keywords:  arsenic trioxide; drug-eluting stent; percutaneous coronary intervention

Year:  2017        PMID: 28413521      PMCID: PMC5377530          DOI: 10.3892/etm.2017.4106

Source DB:  PubMed          Journal:  Exp Ther Med        ISSN: 1792-0981            Impact factor:   2.447


  20 in total

Review 1.  Coated stents for the prevention of restenosis: Part I.

Authors:  Mohan N Babapulle; Mark J Eisenberg
Journal:  Circulation       Date:  2002-11-19       Impact factor: 29.690

2.  Catheter replacement of the needle in percutaneous arteriography. A new technique.

Authors:  Sven Ivar Seldinger
Journal:  Acta Radiol Suppl (Stockholm)       Date:  2008-08

3.  Clinical, humanistic, and economic outcomes between drug-eluting stent (DES) and bare metal stent (BMS): 18-month follow-up study.

Authors:  Vivian W Lee; Franco W Cheng; Adrian Y Choi; Sam T Fong; Cheuk Man Yu; Bryan P Yan
Journal:  J Med Econ       Date:  2016-10-31       Impact factor: 2.448

4.  The Thrombolysis in Myocardial Infarction (TIMI) trial. Phase I findings.

Authors: 
Journal:  N Engl J Med       Date:  1985-04-04       Impact factor: 91.245

5.  TG-interacting factor transcriptionally induced by AKT/FOXO3A is a negative regulator that antagonizes arsenic trioxide-induced cancer cell apoptosis.

Authors:  Zi-Miao Liu; Hong-Yu Tseng; Ya-Ling Cheng; Bi-Wen Yeh; Wen-Jeng Wu; Huei-Sheng Huang
Journal:  Toxicol Appl Pharmacol       Date:  2015-03-16       Impact factor: 4.219

6.  Use of arsenic trioxide (As2O3) in the treatment of acute promyelocytic leukemia (APL): I. As2O3 exerts dose-dependent dual effects on APL cells.

Authors:  G Q Chen; X G Shi; W Tang; S M Xiong; J Zhu; X Cai; Z G Han; J H Ni; G Y Shi; P M Jia; M M Liu; K L He; C Niu; J Ma; P Zhang; T D Zhang; P Paul; T Naoe; K Kitamura; W Miller; S Waxman; Z Y Wang; H de The; S J Chen; Z Chen
Journal:  Blood       Date:  1997-05-01       Impact factor: 22.113

7.  Arsenic trioxide induces the apoptosis in vascular smooth muscle cells via increasing intracellular calcium and ROS formation.

Authors:  Jing-Xiu Li; Ya-Qi Shen; Ben-Zhi Cai; Jing Zhao; Xiaopeng Bai; Yan-Jie Lu; Xue-Qi Li
Journal:  Mol Biol Rep       Date:  2009-05-13       Impact factor: 2.316

Review 8.  Drug-eluting stents in percutaneous coronary intervention: a benefit-risk assessment.

Authors:  Robert A Byrne; Nikolaus Sarafoff; Adnan Kastrati; Albert Schömig
Journal:  Drug Saf       Date:  2009       Impact factor: 5.606

Review 9.  Arsenical-based cancer drugs.

Authors:  Pierre J Dilda; Philip J Hogg
Journal:  Cancer Treat Rev       Date:  2007-07-10       Impact factor: 12.111

10.  Nine-month angiographic and two-year clinical follow-up of novel biodegradable-polymer arsenic trioxide-eluting stent versus durable-polymer sirolimus-eluting stent for coronary artery disease.

Authors:  Li Shen; Wei Yang; Jia-Sheng Yin; Xue-Bo Liu; Yi-Zhe Wu; Ai-Jun Sun; Ju-Ying Qian; Jun-Bo Ge
Journal:  Chin Med J (Engl)       Date:  2015-03-20       Impact factor: 2.628

View more
  2 in total

1.  Levels of leachable elements from long-term use of enFlow fluid warmer.

Authors:  Danielle Bayoro; Herman Groepenhoff; Michael Pedro; Edward A Rose; Andreas D Waldmann
Journal:  SAGE Open Med       Date:  2022-07-05

2.  miR-22 Is a Novel Mediator of Vascular Smooth Muscle Cell Phenotypic Modulation and Neointima Formation.

Authors:  Feng Yang; Qishan Chen; Shiping He; Mei Yang; Eithne Margaret Maguire; Weiwei An; Tayyab Adeel Afzal; Le Anh Luong; Li Zhang; Qingzhong Xiao
Journal:  Circulation       Date:  2017-12-15       Impact factor: 29.690

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.