Literature DB >> 28413075

Abrasion and blunt tissue trauma study of a novel flexible robotic system in the porcine model.

Michael Z Lerner1, Michael Tricoli2, Marshall Strome2.   

Abstract

OBJECTIVES: The objective of this study was to determine if a flexible robotic system caused increased tissue reaction when accessing the oropharynx and hypopharynx compared to intubation controls in only 2 scenarios: high speed tissue impact and multiple unit insertions and retractions. The data obtained were submitted as part of the entirety of information submitted for FDA approval.
METHODS: This study consisted of 5 groups of Yorkshire pigs (2 animals per group). On Day 0, all animals were intubated. For group 1 (control), a second endotracheal tube was advanced to just above the vocal cords. In abrasion groups 2 and 3, the flexible robotic system was advanced against the oropharyngeal and hypopharyngeal tissues, respectively. In blunt trauma groups 4 and 5, the flexible robotic system was advanced at maximum speed (22mm/s) to collide with oropharyngeal and hypopharyngeal tissues, respectively. Pre- and post-procedure endoscopic assessments of tissue reaction were performed daily for 4 days. An independent reviewer graded tissue reaction using a 0-3 point scale.
RESULTS: Tissue reaction scores at each observation time point for all test groups were less than or equal to control scores except for one instance of moderate scoring (2 out of 3) on Day 2 for an animal in the blunt trauma group where reaction was likely intubation-related rather than device impact related. Otherwise, all flexible robotic system-treated animal scores were less than 1 by Day 4.
CONCLUSIONS: In this limited study, the flexrobotic system afforded surgical access to the oropharynx and hypopharynx without an increased level of abrasion or tissue trauma when compared to intubation alone.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Flex robotic system; Head and neck cancer (HNC); Medrobotics; Minimally invasive surgery (MIS); Transoral robotic surgery (TORS)

Mesh:

Year:  2017        PMID: 28413075     DOI: 10.1016/j.amjoto.2017.04.002

Source DB:  PubMed          Journal:  Am J Otolaryngol        ISSN: 0196-0709            Impact factor:   1.808


  1 in total

1.  Flexible transoral robotic surgery: the Italian experience.

Authors:  Francesco Barbara; Francesco Cariti; Valentina De Robertis; Michele Barbara
Journal:  Acta Otorhinolaryngol Ital       Date:  2021-02       Impact factor: 2.124

  1 in total