Literature DB >> 28411815

Automation of sample processing for ICP-MS determination of 90Sr radionuclide at ppq level for nuclear technology and environmental purposes.

Kamila Kołacińska1, Ewelina Chajduk1, Jakub Dudek1, Zbigniew Samczyński1, Edyta Łokas2, Anna Bojanowska-Czajka1, Marek Trojanowicz3.   

Abstract

90Sr is a widely determined radionuclide for environmental purposes, nuclear waste control, and can be also monitored in coolants in nuclear reactor plants. In the developed method, the ICP-MS detection was employed together with sample processing in sequential injection analysis (SIA) setup, equipped with a lab-on-valve with mechanized renewal of sorbent bed for solid-phase extraction. The optimized conditions of determination included preconcentration of 90Sr on cation-exchange column and removal of different type of interferences using extraction Sr-resin. The limit of detection of the developed procedure depends essentially on the configuration of the employed ICP-MS spectrometer and on the available volume of the sample to be analyzed. For 1L initial sample volume, the method detection limit (MDL) value was evaluated as 2.9ppq (14.5BqL-1). The developed method was applied to analyze spiked river water samples, water reference materials, and also simulated and real samples of the nuclear reactor coolant.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Environmental analysis; Extraction resin; ICP-MS; Nuclear reactor coolant; Solid-phase extraction; Strontium-90

Year:  2016        PMID: 28411815     DOI: 10.1016/j.talanta.2016.10.051

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  7 in total

1.  Sr-Nd-Hf isotopic analysis of reference materials and natural and anthropogenic particulate matter sources: Implications for accurately tracing North African dust in complex urban atmospheres.

Authors:  Sourav Das; Brent V Miller; Joseph Prospero; Shankararaman Chellam
Journal:  Talanta       Date:  2022-01-19       Impact factor: 6.057

Review 2.  Flow-Injection Methods in Water Analysis-Recent Developments.

Authors:  Marek Trojanowicz; Marta Pyszynska
Journal:  Molecules       Date:  2022-02-19       Impact factor: 4.411

3.  Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level.

Authors:  Victor Vicente Vilas; Sylvain Millet; Miguel Sandow; Laura Aldave de Las Heras
Journal:  J Vis Exp       Date:  2018-06-06       Impact factor: 1.355

Review 4.  Flow Chemistry in Contemporary Chemical Sciences: A Real Variety of Its Applications.

Authors:  Marek Trojanowicz
Journal:  Molecules       Date:  2020-03-21       Impact factor: 4.411

5.  An Automated SeaFAST ICP-DRC-MS Method for the Determination of 90Sr in Spent Nuclear Fuel Leachates.

Authors:  Víctor Vicente Vilas; Sylvain Millet; Miguel Sandow; Luis Iglesias Pérez; Daniel Serrano-Purroy; Stefaan Van Winckel; Laura Aldave de Las Heras
Journal:  Molecules       Date:  2020-03-21       Impact factor: 4.411

Review 6.  Dynamic Flow Approaches for Automated Radiochemical Analysis in Environmental, Nuclear and Medical Applications.

Authors:  Jixin Qiao
Journal:  Molecules       Date:  2020-03-24       Impact factor: 4.411

7.  Online Solid-Phase Extraction-Inductively Coupled Plasma-Quadrupole Mass Spectrometry with Oxygen Dynamic Reaction for Quantification of Technetium-99.

Authors:  Makoto Matsueda; Kayo Yanagisawa; Kazuma Koarai; Motoki Terashima; Kenso Fujiwara; Hironobu Abe; Akihiro Kitamura; Yoshitaka Takagai
Journal:  ACS Omega       Date:  2021-07-16
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.