Literature DB >> 28411814

Nanocoating cellulose paper based microextraction combined with nanospray mass spectrometry for rapid and facile quantitation of ribonucleosides in human urine.

Lingzhong Wan1, Haijing Zhu1, Yafeng Guan2, Guangming Huang3.   

Abstract

A rapid and facile analytical method for quantification of ribonucleosides in human urine was developed by the combination of nanocoating cellulose paper based microextraction and nanoelectrospray ionization-tandem mass spectrometry (nESI-MS/MS). Cellulose paper used for microextraction was modified by nano-precision deposition of uniform ultrathin zirconia gel film using a sol-gel process. Due to the large surface area of the cellulose paper and the strong affinity between zirconia and the cis-diol compounds, the target analytes were selectively extracted from the complex matrix. Thus, the detection sensitivity was greatly improved. Typically, the nanocoating cellulose paper was immersed into the diluted urine for selective extraction of target analytes, then the extracted analytes were subjected to nESI-MS/MS detection. The whole analytical procedure could be completed within 10min. The method was evaluated by the determination of ribonucleosides (adenosine, cytidine, uridine, guanosine) in urine sample. The signal intensities of the ribonuclesides extracted by the nanocoating cellulose paper were greatly enhanced by 136-459-folds compared with the one of the unmodified cellulose paper based microextraction. The limits of detection (LODs) and the limits of quantification (LOQs) of the four ribonucleosides were in the range of 0.0136-1.258μgL-1 and 0.0454-4.194μgL-1, respectively. The recoveries of the target nucleosides from spiked human urine were in the range of 75.64-103.49% with the relative standard deviations (RSDs) less than 9.36%. The results demonstrate the potential of the proposed method for rapid and facile determination of endogenous ribonucleosides in urine sample.
Copyright © 2017. Published by Elsevier B.V.

Entities:  

Keywords:  Nanocoating cellulose paper based microextraction; Nanospray mass spectrometry; Ribonucleosides; Zirconia

Mesh:

Substances:

Year:  2017        PMID: 28411814     DOI: 10.1016/j.talanta.2017.03.085

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Extraction of nucleobases, nucleosides and nucleotides by employing a magnetized graphene oxide functionalized with hydrophilic phytic acid and titanium(IV) ions.

Authors:  Qian Zhang; Dong-Dong Zhou; Fan Li; Yin-Zhen Wang; Feng-Qing Yang
Journal:  Mikrochim Acta       Date:  2019-02-15       Impact factor: 5.833

2.  LC-MS/MS determination of plasma catecholamines after selective extraction by borated zirconia.

Authors:  Juan Le; Ting Sun; Rui Peng; Teng-Fei Yuan; Yu-Qi Feng; Shao-Ting Wang; Yan Li
Journal:  Mikrochim Acta       Date:  2020-02-12       Impact factor: 5.833

  2 in total