Relations between doses cumulated in bone marrow and dose delivery techniques during radiation therapy of cervical and endometrial cancer.

Agata Jodda1, Bartosz Urbański2, Tomasz Piotrowski3, Julian Malicki3.   

Abstract

PURPOSE: To compare normal tissue complication probability (NTCP) and average doses in the bone marrow (BM), obtained for five different radiotherapy delivery and planning strategies of cervical and endometrial cancer. MATERIAL/
METHODS: 50 patients were taken to analysis. For each case, 3 different dose delivery techniques were used: 4-field, X15MV, 3DCRT; 7-field, X6MV, IMRT; and 2-arc, X6MV, VMAT. Two optimization scenarios were used for the IMRT and VMAT plans generation: with (+) and without (-) the inclusion of the BM as an optimized structure. Average doses and dose-volume histogram parameters for the PTV, BM, bladder, rectum, bowels and femoral heads were compared. In addition, the BM doses were analyzed with respect to the PTV and/or volume of the BM, and NTCP for the BM were computed.
RESULTS: The dose in PTV for evaluated plans was similar. The worst doses in organs at risk were obtained for 3DCRT. Using the BM during the optimization of IMRT and VMAT reduces an average dose in BM without increasing the doses in the bladder, rectum and bowels. Differences between doses in BM for IMRT(+) and VMAT(+) plans were similar while NTCP was lower for VMAT(+). A correlation between average dose in BM and the volume ratio of BM and PTV was found for each technique.
CONCLUSION: Using the BM during the optimization of the IMRT and VMAT plans effectively reduces the dose in BM without increasing the dose in the bladder, rectum and bowels. The VMAT(+) plans were characterized by the lowest NTCP.
Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone marrow; Gynecological cancer; IMRT; NTCP modeling; Optimization strategies; VMAT

Mesh:

Year:  2017        PMID: 28410686     DOI: 10.1016/j.ejmp.2017.03.006

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  4 in total

1.  Dosimetric impact of Acuros XB on cervix radiotherapy using RapidArc technique: a dosimetric study.

Authors:  Lalit Kumar; Vimal Kishore; Manindra Bhushan; Pawan Kumar; Rahul Lal Chaudhary
Journal:  Rep Pract Oncol Radiother       Date:  2021-08-12

2.  Impact of different optimization strategies on the compatibility between planned and delivered doses during radiation therapy of cervical cancer.

Authors:  Agata Jodda; Tomasz Piotrowski; Marta Kruszyna-Mochalska; Julian Malicki
Journal:  Rep Pract Oncol Radiother       Date:  2020-04-12

3.  Half-beam volumetric-modulated arc therapy in adjuvant radiotherapy for gynecological cancers.

Authors:  Pei-Chieh Yu; Ching-Jung Wu; Hsin-Hua Nien; Louis Tak Lui; Suzun Shaw; Yu-Lun Tsai
Journal:  J Appl Clin Med Phys       Date:  2021-11-16       Impact factor: 2.102

4.  Correlation between pelvic bone marrow radiation dose and acute hematological toxicity in cervical cancer patients treated with concurrent chemoradiation.

Authors:  T Kumar; A Schernberg; F Busato; M Laurans; I Fumagalli; I Dumas; E Deutsch; C Haie-Meder; C Chargari
Journal:  Cancer Manag Res       Date:  2019-07-08       Impact factor: 3.989

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.