Literature DB >> 28407287

Reproducibility of three dimensional digital preoperative planning for the osteosynthesis of distal radius fractures.

Yuichi Yoshii1, Takuya Kusakabe1, Kenichi Akita2, Wen Lin Tung3, Tomoo Ishii1.   

Abstract

A three-dimensional (3D) digital preoperative planning system for the osteosynthesis of distal radius fractures was developed for clinical practice. To assess the usefulness of the 3D planning for osteosynthesis, we evaluated the reproducibility of the reduction shapes and selected implants in the patients with distal radius fractures. Twenty wrists of 20 distal radius fracture patients who underwent osteosynthesis using volar locking plates were evaluated. The 3D preoperative planning was performed prior to each surgery. Four surgeons conducted the surgeries. The surgeons performed the reduction and the placement of the plate while comparing images between the preoperative plan and fluoroscopy. Preoperative planning and postoperative reductions were compared by measuring volar tilt and radial inclination of the 3D images. Intra-class correlation coefficients (ICCs) of the volar tilt and radial inclination were evaluated. For the implant choices, the ICCs for the screw lengths between the preoperative plan and the actual choices were evaluated. The ICCs were 0.644 (p < 0.01) and 0.625 (p < 0.01) for the volar tilt and radial inclination in the 3D measurements, respectively. The planned size of plate was used in all of the patients. The ICC for the screw length between preoperative planning and actual choice was 0.860 (p < 0.01). Good reproducibility for the reduction shape and excellent reproducibility for the implant choices were achieved using 3D preoperative planning for distal radius fracture. Three-dimensional digital planning was useful to visualize the reduction process and choose a proper implant for distal radius fractures.
© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2646-2651, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  computed tomography; distal radius fracture; locking plate; osteosynthesis; three dimensional

Mesh:

Year:  2017        PMID: 28407287     DOI: 10.1002/jor.23578

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Utility of an image fusion system for 3D preoperative planning and fluoroscopy in the osteosynthesis of distal radius fractures.

Authors:  Yuichi Yoshii; Yasukazu Totoki; Satoshi Sashida; Shinsuke Sakai; Tomoo Ishii
Journal:  J Orthop Surg Res       Date:  2019-11-06       Impact factor: 2.359

2.  Three-dimensional evaluations of preoperative planning reproducibility for the osteosynthesis of distal radius fractures.

Authors:  Yuichi Yoshii; Takeshi Ogawa; Atsuo Shigi; Kunihiro Oka; Tsuyoshi Murase; Tomoo Ishii
Journal:  J Orthop Surg Res       Date:  2021-02-12       Impact factor: 2.359

3.  3D virtual pre-operative planning may reduce the incidence of dorsal screw penetration in volar plating of intra-articular distal radius fractures.

Authors:  Jasper Prijs; Bram Schoolmeesters; Denise Eygendaal; Jean-Paul P M de Vries; Paul C Jutte; Job N Doornberg; Ruurd L Jaarsma; Frank F A IJpma
Journal:  Eur J Trauma Emerg Surg       Date:  2021-10-08       Impact factor: 2.374

4.  Association of Computer-Assisted Virtual Preoperative Planning With Postoperative Mortality and Complications in Older Patients With Intertrochanteric Hip Fracture.

Authors:  Xiaoyang Jia; Kun Zhang; Minfei Qiang; Ying Wu; Yanxi Chen
Journal:  JAMA Netw Open       Date:  2020-08-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.