Literature DB >> 28407166

Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens.

Vyas Akondi, Pablo Pérez-Merino, Eduardo Martinez-Enriquez, Carlos Dorronsoro, Nicolás Alejandre, Ignacio Jiménez-Alfaro, Susana Marcos.   

Abstract

PURPOSE: Standard evaluation of aberrations from wavefront slope measurements in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), results in large magnitude primary vertical coma, which is attributed to the intrinsic IOL design. The new proposed method analyzes aberrometry data, allowing disentangling the IOL power pupillary distribution from the true higher order aberrations of the eye.
METHODS: The new method of wavefront reconstruction uses retinal spots obtained at both the near and far foci. The method was tested using ray tracing optical simulations in a computer eye model virtually implanted with the Lentis Mplus IOL, with a generic cornea or with anterior segment geometry obtained from custom quantitative spectral-domain optical coherence tomography in a real patient. The method was applied to laser ray tracing aberrometry data at near and far fixation obtained in a patient implanted with the Lentis Mplus IOL.
RESULTS: Higher order aberrations evaluated from simulated and real retinal spot diagrams following the new reconstruction approach matched the nominal aberrations (approximately 98%). Previously reported primary vertical coma in patients implanted with this IOL lost significance with the application of the proposed reconstruction.
CONCLUSIONS: Custom analysis of ray tracing-based retinal spot diagrams allowed decoupling of the true higher order aberrations of the patient's eye from the power pupillary distribution of a rotationally asymmetric multifocal IOL, therefore providing the appropriate phase map to accurately evaluate through-focus optical quality. [J Refract Surg. 2017;33(4):257-265.]. Copyright 2017, SLACK Incorporated.

Entities:  

Mesh:

Year:  2017        PMID: 28407166     DOI: 10.3928/1081597X-20161206-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  12 in total

1.  Experimental validations of a tunable-lens-based visual demonstrator of multifocal corrections.

Authors:  Vyas Akondi; Lucie Sawides; Yassine Marrakchi; Enrique Gambra; Susana Marcos; Carlos Dorronsoro
Journal:  Biomed Opt Express       Date:  2018-11-15       Impact factor: 3.732

2.  Multi-layer Shack-Hartmann wavefront sensing in the point source regime.

Authors:  Vyas Akondi; Alfredo Dubra
Journal:  Biomed Opt Express       Date:  2020-12-16       Impact factor: 3.732

3.  Pre-operative simulation of post-operative multifocal vision.

Authors:  Maria Vinas; Sara Aissati; Mercedes Romero; Clara Benedi-Garcia; Nuria Garzon; Francisco Poyales; Carlos Dorronsoro; Susana Marcos
Journal:  Biomed Opt Express       Date:  2019-10-21       Impact factor: 3.732

4.  Temporal multiplexing to simulate multifocal intraocular lenses: theoretical considerations.

Authors:  Vyas Akondi; Carlos Dorronsoro; Enrique Gambra; Susana Marcos
Journal:  Biomed Opt Express       Date:  2017-06-23       Impact factor: 3.732

5.  Visual simulators replicate vision with multifocal lenses.

Authors:  Maria Vinas; Clara Benedi-Garcia; Sara Aissati; Daniel Pascual; Vyas Akondi; Carlos Dorronsoro; Susana Marcos
Journal:  Sci Rep       Date:  2019-02-07       Impact factor: 4.379

Review 6.  Bifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control.

Authors:  Laura Remón; Pablo Pérez-Merino; Rute J Macedo-de-Araújo; Ana I Amorim-de-Sousa; José M González-Méijome
Journal:  J Ophthalmol       Date:  2020-03-27       Impact factor: 1.909

7.  Visual Performance Following Bilateral Implantation of Refractive Rotationally Asymmetric Bifocal Intraocular Lens (LS-313 MF30) or Apodized Diffractive Bifocal Intraocular Lens (ReSTOR SN6AD1).

Authors:  Honglei Li; Dongle Liu; Han Gao; Jiajun Sun; Huiran Bai; Xiaoming Wu
Journal:  Ther Clin Risk Manag       Date:  2021-09-01       Impact factor: 2.423

Review 8.  Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of IOLs: A Meta-Analysis.

Authors:  Zequan Xu; Wenzhe Li; Lianqun Wu; Shuang Xue; Xu Chen; Qiang Wu
Journal:  J Ophthalmol       Date:  2018-09-27       Impact factor: 1.909

9.  Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens.

Authors:  Xiao Wang; Haixia Tu; Yong Wang
Journal:  J Ophthalmol       Date:  2020-04-20       Impact factor: 1.909

Review 10.  Extended Depth-of-Field Intraocular Lenses: An Update.

Authors:  Piotr Kanclerz; Francesca Toto; Andrzej Grzybowski; Jorge L Alio
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2020 May-Jun
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.