Literature DB >> 28402627

Strategy for the Quantitation of a Protein Conjugate via Hybrid Immunocapture-Liquid Chromatography with Sequential HRMS and SRM-Based LC-MS/MS Analyses.

Yue Zhao1, Guowen Liu1, Xiling Yuan1, Jinping Gan1, Jon E Peterson1, Jim X Shen1.   

Abstract

With the development of modern instrumentation and technologies, mass spectrometry based assays have played an important role in protein bioanalysis. We have developed a novel strategy by combining the "bottom-up" and "top-down" approaches using both high-resolution (HRMS) and selected reaction monitoring (SRM) based mass spectrometric detection to quantify a positron emission tomography (PET) detection tracer for an oncology marker. Monkey plasma samples were processed by immunocapture purification, followed by liquid chromatography (LC) with HRMS full scan analysis. Summed multiple charge states and multiple isotopes per charge state of the analyte were used during quantitation for optimized sensitivity. After the HRMS analysis, the remaining samples were digested by trypsin, followed by SRM detection. The HRMS approach provided the solution to a unique problem related to stability of the protein conjugate by quantifying the intact protein. The SRM method only measured a signature peptide generated from enzymatic digestion, but had a lower quantitation limit to meet the sensitivity requirement to assess the pharmacokinetics in a toxicology study. Both methods demonstrated good sensitivity, accuracy, precision and robustness, and the results revealed that there was no significant difference between the data sets obtained from both methods, indicating no in vivo or ex vivo degradation occurred in the incurred samples after dosing. This workflow not only provided the quantitative results for pharmacokinetic evaluation, but also revealed valuable in vivo stability information on the intact protein level.

Mesh:

Substances:

Year:  2017        PMID: 28402627     DOI: 10.1021/acs.analchem.7b00926

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  Aptamer-functionalized magnetic and fluorescent nanospheres for one-step sensitive detection of thrombin.

Authors:  Cong-Ying Wen; Jia-Hui Bi; Ling-Ling Wu; Jing-Bin Zeng
Journal:  Mikrochim Acta       Date:  2017-12-22       Impact factor: 5.833

2.  Characterization and Quantification of an Fc-FGF21 Fusion Protein in Rat Serum Using Immunoaffinity LC-MS.

Authors:  Fengping Li; Yan Weng; Guodong Zhang; Xiaogang Han; Dongmei Li; Hendrik Neubert
Journal:  AAPS J       Date:  2019-07-08       Impact factor: 4.009

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.