Literature DB >> 28402121

In Situ Underwater Laser-Induced Breakdown Spectroscopy Analysis for Trace Cr(VI) in Aqueous Solution Supported by Electrosorption Enrichment and a Gas-Assisted Localized Liquid Discharge Apparatus.

Tian-Jia Jiang1,2, Meng Yang1,2, Shan-Shan Li1,2, Ming-Jun Ma3, Nan-Jing Zhao3, Zheng Guo1,2, Jin-Huai Liu, Xing-Jiu Huang1,2.   

Abstract

Traditional laser-induced breakdown spectroscopy (LIBS) always fails to directly detect target in aqueous solution due to rapid quenching of emitted light and adsorption of pulse energy by surrounding water. A method is proposed for the in situ underwater LIBS analysis of Cr(VI) in aqueous solution freed from the common problems mentioned above by combining a gas-assisted localized liquid discharge apparatus with electrosorption for the first time. In this approach, the introduction of the gas-assisted localized liquid discharge apparatus provides an instantaneous gaseous environment for underwater LIBS measurement (that is, the transfer of sampling matrix is not needed from aqueous solution to dry state). The preconcentration of Cr(VI) is achieved by electrosorption with a positive potential applied around adsorbents, which can promote the adsorption of Cr(VI) and inhibit that of the coexisting cations leading to a good anti-interference. Amino groups functionalized chitosan-modified graphene oxide (CS-GO) is utilized for Cr(VI) enrichment, which can be protonated to form NH3+ in acidic condition promoting the adsorption toward Cr(VI) by electrostatic attraction. The highest detection sensitivity of 5.15 counts μg-1 L toward Cr(VI) is found for the optimized electrosorption potential (EES = 1.5 V) and electrosorption time (tES = 600 s) without interference from coexisting metal ions. A corresponding limit of detection (LOD) of 12.3 μg L-1 (3σ method) is achieved, which is amazingly improved by 2 or even 3 orders of magnitude compared to the previous reports of LIBS.

Entities:  

Year:  2017        PMID: 28402121     DOI: 10.1021/acs.analchem.7b00629

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  2 in total

1.  An efficient and reusable quaternary ammonium fabric adsorbent prepared by radiation grafting for removal of Cr(VI) from wastewater.

Authors:  Li-Juan Pang; Jiang-Tao Hu; Mao-Jiang Zhang; Chen-Guang Yang; Guo-Zhong Wu
Journal:  Environ Sci Pollut Res Int       Date:  2018-02-06       Impact factor: 4.223

2.  Cationic Metal-Organic Framework-Based Mixed-Matrix Membranes for Fast Sensing and Removal of Cr2O7 2- Within Water.

Authors:  Shuyun Zhang; Heqi Zheng; Yu Yang; Guodong Qian; Yuanjing Cui
Journal:  Front Chem       Date:  2022-02-28       Impact factor: 5.221

  2 in total