Literature DB >> 28400204

Computed navigated total knee arthroplasty compared to computed tomography scans.

Ron Batash1, Guy Rubin2, Alexander Lerner3, Hussein Shehade4, Nimrod Rozen2, David E Rothem5.   

Abstract

BACKGROUND: Successful total knee arthroplasty (TKA) includes accurate alignment. Controversy remains as to whether computer-navigated TKA improves the overall result and clinical outcome. Our aim is to compare the limb alignment and prosthesis positioning according to the pre- and postoperative computed tomography (CT) scans with the data collected from the navigation system.
METHODS: We compared the pre- and postoperative limb alignments and prosthesis alignment provided by the Orthopilot navigation system, Aesculap®, with CT scans measured by the Traumacad® software of 70 TKAs.
RESULTS: A positive correlation with statistical significance (P=0.00001, r=0.874) between the navigation system data and the CT images was found. Mean femoral cut was five degrees (valgus), and mean tibial cut was one degree (varus). Our study revealed that the navigation system assisted the surgeon to implant the prosthesis at a good acceptable alignment.
CONCLUSION: We found that the navigation system is accurate and correlates to the pre- and postoperative CT scans. Furthermore, the navigation system can assist the surgeon to achieve good limb alignment and cutting planes of the prosthesis.
Copyright © 2017 Elsevier B.V. All rights reserved.

Keywords:  Computed tomography; Navigation; Total knee arthroplasty

Mesh:

Year:  2017        PMID: 28400204     DOI: 10.1016/j.knee.2017.03.006

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  3 in total

1.  Importance of the gender and preoperative knee sagittal alignment to avoid unnecessary tibial resection in TKR.

Authors:  Carlos Daniel Novoa-Parra; R Sanjuan-Cerveró; N H de la Iglesia; N Franco-Ferrando; R Larrainzar-Garijo; A Lizaur-Utrilla
Journal:  Eur J Orthop Surg Traumatol       Date:  2020-09-04

2.  Knee arthroplasty with hardware removal: complication cascade. Is it preventable?

Authors:  Gabriel Nierenberg; Alaa Abu Elasal; Eran Keltz; Doron Norman
Journal:  BMJ Case Rep       Date:  2020-08-24

3.  The Effect of Position on Radiographic Angle Measurements of the Lower Extremities.

Authors:  Jeehyeok Chung; Joonhee Lee; Hyuk-Soo Han; Myung Chul Lee; Du Hyun Ro
Journal:  Biomed Res Int       Date:  2022-03-07       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.