Magnetic field influences on the lateral dose response functions of photon-beam detectors: MC study of wall-less water-filled detectors with various densities.

Hui Khee Looe1, Björn Delfs, Daniela Poppinga, Dietrich Harder, Björn Poppe.   

Abstract

The distortion of detector reading profiles across photon beams in the presence of magnetic fields is a developing subject of clinical photon-beam dosimetry. The underlying modification by the Lorentz force of a detector's lateral dose response function-the convolution kernel transforming the true cross-beam dose profile in water into the detector reading profile-is here studied for the first time. The three basic convolution kernels, the photon fluence response function, the dose deposition kernel, and the lateral dose response function, of wall-less cylindrical detectors filled with water of low, normal and enhanced density are shown by Monte Carlo simulation to be distorted in the prevailing direction of the Lorentz force. The asymmetric shape changes of these convolution kernels in a water medium and in magnetic fields of up to 1.5 T are confined to the lower millimetre range, and they depend on the photon beam quality, the magnetic flux density and the detector's density. The impact of this distortion on detector reading profiles is demonstrated using a narrow photon beam profile. For clinical applications it appears as favourable that the magnetic flux density dependent distortion of the lateral dose response function, as far as secondary electron transport is concerned, vanishes in the case of water-equivalent detectors of normal water density. By means of secondary electron history backtracing, the spatial distribution of the photon interactions giving rise either directly to secondary electrons or to scattered photons further downstream producing secondary electrons which contribute to the detector's signal, and their lateral shift due to the Lorentz force is elucidated. Electron history backtracing also serves to illustrate the correct treatment of the influences of the Lorentz force in the EGSnrc Monte Carlo code applied in this study.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28398218     DOI: 10.1088/1361-6560/aa6ca0

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Relative dosimetry with an MR-linac: Response of ion chambers, diamond, and diode detectors for off-axis, depth dose, and output factor measurements.

Authors:  Daniel J O'Brien; James Dolan; Stefan Pencea; Nicholas Schupp; Gabriel O Sawakuchi
Journal:  Med Phys       Date:  2017-12-21       Impact factor: 4.071

2.  Impact of magnetic fields on dose measurement with small ion chambers illustrated in high-resolution response maps.

Authors:  Joerg Lehmann; Toby Beveridge; Chris Oliver; Tracy E Bailey; Jessica E Lye; Jayde Livingstone; Andrew W Stevenson; Duncan J Butler
Journal:  Med Phys       Date:  2019-06-11       Impact factor: 4.071

Review 3.  Medical physics challenges in clinical MR-guided radiotherapy.

Authors:  Christopher Kurz; Giulia Buizza; Guillaume Landry; Florian Kamp; Moritz Rabe; Chiara Paganelli; Guido Baroni; Michael Reiner; Paul J Keall; Cornelis A T van den Berg; Marco Riboldi
Journal:  Radiat Oncol       Date:  2020-05-05       Impact factor: 3.481

4.  Characterization of EBT3 radiochromic films for dosimetry of proton beams in the presence of magnetic fields.

Authors:  Fatima Padilla-Cabal; Peter Kuess; Dietmar Georg; Hugo Palmans; Lukas Fetty; Hermann Fuchs
Journal:  Med Phys       Date:  2019-05-31       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.