Literature DB >> 28396178

Magnetic resonance imaging basics for the prostate brachytherapist.

Jihong Wang1, Kari Tanderup2, Adam Cunha3, Antonio L Damato4, Gil'ad N Cohen4, Rajat J Kudchadker5, Firas Mourtada6.   

Abstract

Magnetic resonance imaging (MRI) is increasingly being used in radiation therapy, and integration of MRI into brachytherapy in particular is becoming more common. We present here a systematic review of the basic physics and technical aspects of incorporating MRI into prostate brachytherapy. Terminology and MRI system components are reviewed along with typical work flows in prostate high-dose-rate and low-dose-rate brachytherapy. In general, the brachytherapy workflow consists of five key components: diagnosis, implantation, treatment planning (scan + plan), implant verification, and delivery. MRI integration is discussed for diagnosis; treatment planning; and MRI-guided brachytherapy implants, in which MRI is used to guide the physical insertion of the brachytherapy applicator or needles. Considerations and challenges for establishing an MRI brachytherapy program are also discussed.
Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Keywords:  Brachytherapy; HDR; LDR; MRI; Prostate; Quality assurance

Year:  2017        PMID: 28396178     DOI: 10.1016/j.brachy.2017.03.004

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  4 in total

Review 1.  [Imaging of locally advanced prostate cancer : Importance of ultrasound and especially MRI].

Authors:  O Solyanik; B Schlenker; C Gratzke; B Ertl-Wagner; D A Clevert; C Stief; J Ricke; D Nörenberg
Journal:  Urologe A       Date:  2017-11       Impact factor: 0.639

2.  Multiparametric MRI for prostate cancer: a national survey of patterns of practice among radiation oncologists in Spain.

Authors:  F Couñago; G Sancho; A Gómez-Iturriaga; I Henríquez
Journal:  Clin Transl Oncol       Date:  2018-07-10       Impact factor: 3.405

Review 3.  [MRI-guided minimally invasive treatment of prostate cancer].

Authors:  Fabian Tollens; Niklas Westhoff; Jost von Hardenberg; Sven Clausen; Michael Ehmann; Frank G Zöllner; Anne Adlung; Dominik F Bauer; Stefan O Schoenberg; Dominik Nörenberg
Journal:  Radiologe       Date:  2021-07-12       Impact factor: 0.635

4.  Simple phantom fabrication for MRI-based HDR brachytherapy applicator commissioning.

Authors:  Jessica M Fagerstrom; Sukhjit Kaur
Journal:  J Appl Clin Med Phys       Date:  2020-10-05       Impact factor: 2.243

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.