| Literature DB >> 28393759 |
M Aymerich1, E Álvarez, C Bao-Varela, I Moscoso, J R González-Juanatey, M T Flores-Arias.
Abstract
In this work a method for fabricating functionalized preclinical devices is presented. The manufacturing process combines a laser indirect writing technique to fabricate a soda-lime glass master and soft-lithography methods to obtain the final structure in polydimethylsiloxane (PDMS). The roughness of the device is modified in a controlled manner by applying a post-thermal treatment to the master, and thus devices with different roughness values are created. The PDMS devices are fully covered with human umbilical vein cells in a two-step process. In order to determine the most suitable device to perform bioassays, the cell attachment to the channel is evaluated with regards to the walls roughness when flow experiments are carried out.Entities:
Mesh:
Substances:
Year: 2017 PMID: 28393759 DOI: 10.1088/1758-5090/aa6c3d
Source DB: PubMed Journal: Biofabrication ISSN: 1758-5082 Impact factor: 9.954