| Literature DB >> 28386503 |
Amna Qasim1, Soham Dasgupta1, Sunil K Jain2, Amyn K Jiwani3, Ashraf M Aly3.
Abstract
Surgical ligation of a patent ductus arteriosus (PDA) is a commonly performed procedure. Complications are infrequent and most commonly include recurrent laryngeal nerve injury and rarely ligation of left pulmonary artery. We report a case of accidental ligation of the descending thoracic aorta leading to a clinically significant coarctation.Entities:
Year: 2017 PMID: 28386503 PMCID: PMC5366793 DOI: 10.1155/2017/2647353
Source DB: PubMed Journal: Case Rep Pediatr
Figure 1Echocardiogram (suprasternal view) demonstrating a normal aortic arch without any evidence of coarctation prior to patent ductus arteriosus ligation surgery.
Figure 2Echocardiogram demonstrating juxtaductal coarctation of the aorta following patent ductus arteriosus ligation surgery.