A UHPLC method for the rapid separation and quantification of phytosterols using tandem UV/Charged aerosol detection - A comparison of both detection techniques.

Jakub Fibigr1, Dalibor Šatínský2, Petr Solich1.   

Abstract

The presented work describes the development and validation of a rapid UHPLC-UV/CAD method using a core-shell particle column for the separation and quantitative analysis of seven plant sterols and stanols. The phytosterols (ergosterol, brassicasterol, campesterol, fucosterol, stigmasterol, and β-sitosterol) and the phytostanol stigmastanol were separated and analyzed in 8.5min. The sample pre-treatment procedure was optimized to be less time-consuming than any other published method, especially due to no need of derivatization, evaporation and even reconstitution step. The chromatographic separation was performed on the Kinetex 1.7μ Phenyl-hexyl column (100×2.1mm) with a mobile phase acetonitrile/water according to the gradient program at a flow rate of 0.9mLmin-1 and a temperature of 60°C. A tandem connection of PDA and CAD (Corona Charged Aerosol Detector) was used and both detection techniques were compared. The method was validated using saponification as a first step in sample pre-treatment and an universal CAD as the detector. Recoveries for all analyzed compounds were between 95.4% and 103.4% and relative standard deviation ranged from 1.0% to 5.8% for within-day and from 1.4% to 6.7% for between-day repeatability. The limits of detection were in the range of 0.4-0.6μgmL-1 for standard solutions and 0.3-1.2μgmL-1 for phytosterols in real samples. Although several gradient programs and different stationary phases were tested, two compounds, campesterol and campestanol, were not separated. Their peak was quantified as a sum of both analytes.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Core–shell column; Corona-charged aerosol detector (CAD); Plant extracts; Plant sterols; Stanols; UHPLC

Mesh:

Substances:

Year:  2017        PMID: 28384622     DOI: 10.1016/j.jpba.2017.03.057

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  2 in total

Review 1.  Molecularly imprinted polymers via reversible addition-fragmentation chain-transfer synthesis in sensing and environmental applications.

Authors:  Irvin Veloz Martínez; Jackeline Iturbe Ek; Ethan C Ahn; Alan O Sustaita
Journal:  RSC Adv       Date:  2022-03-23       Impact factor: 3.361

2.  Development and Validation of a Chromatography Method Using Tandem UV/Charged Aerosol Detector for Simultaneous Determination of Amlodipine Besylate and Olmesartan Medoxomil: Application to Drug-Excipient Compatibility Study.

Authors:  Ariadne M Brondi; Jerusa S Garcia; Marcello G Trevisan
Journal:  J Anal Methods Chem       Date:  2017-12-17       Impact factor: 2.193

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.