Intra- and Interobserver Variability of Cochlear Length Measurements in Clinical CT.

John E Iyaniwura1, Mai Elfarnawany, Sadegh Riyahi-Alam, Manas Sharma, Zahra Kassam, Yves Bureau, Lorne S Parnes, Hanif M Ladak, Sumit K Agrawal.   

Abstract

HYPOTHESIS: The cochlear A-value measurement exhibits significant inter- and intraobserver variability, and its accuracy is dependent on the visualization method in clinical computed tomography (CT) images of the cochlea.
BACKGROUND: An accurate estimate of the cochlear duct length (CDL) can be used to determine electrode choice, and frequency map the cochlea based on the Greenwood equation. Studies have described estimating the CDL using a single A-value measurement, however the observer variability has not been assessed.
METHODS: Clinical and micro-CT images of 20 cadaveric cochleae were acquired. Four specialists measured A-values on clinical CT images using both standard views and multiplanar reconstructed (MPR) views. Measurements were repeated to assess for intraobserver variability. Observer variabilities were evaluated using intra-class correlation and absolute differences. Accuracy was evaluated by comparison to the gold standard micro-CT images of the same specimens.
RESULTS: Interobserver variability was good (average absolute difference: 0.77 ± 0.42 mm) using standard views and fair (average absolute difference: 0.90 ± 0.31 mm) using MPR views. Intraobserver variability had an average absolute difference of 0.31 ± 0.09 mm for the standard views and 0.38 ± 0.17 mm for the MPR views. MPR view measurements were more accurate than standard views, with average relative errors of 9.5 and 14.5%, respectively.
CONCLUSION: There was significant observer variability in A-value measurements using both the standard and MPR views. Creating the MPR views increased variability between experts, however MPR views yielded more accurate results. Automated A-value measurement algorithms may help to reduce variability and increase accuracy in the future.

Entities:  

Mesh:

Year:  2017        PMID: 28383464     DOI: 10.1097/MAO.0000000000001411

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  2 in total

1.  An automated A-value measurement tool for accurate cochlear duct length estimation.

Authors:  John E Iyaniwura; Mai Elfarnawany; Hanif M Ladak; Sumit K Agrawal
Journal:  J Otolaryngol Head Neck Surg       Date:  2018-01-22

2.  Morphological validation of a novel bi-material 3D-printed model of temporal bone for middle ear surgery education.

Authors:  Jordan Chauvelot; Cedric Laurent; Gaël Le Coz; Jean-Philippe Jehl; Nguyen Tran; Marta Szczetynska; Abdelhadi Moufki; Anne-Sophie Bonnet; Cecile Parietti-Winkler
Journal:  Ann Transl Med       Date:  2020-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.