Literature DB >> 2838207

Porous hydroxyapatite and tricalcium phosphate cylinders with two different pore size ranges implanted in the cancellous bone of rabbits. A comparative histomorphometric and histologic study of bony ingrowth and implant substitution.

P S Eggli1, W Müller, R K Schenk.   

Abstract

To investigate the histophysiology of implant degradation, hydroxyapatite and tricalcium phosphate cylinders with a diameter of 3 mm were implanted in the cancellous bone of the distal femur and the proximal tibia of 15 New Zealand White rabbits for up to six months. All implants had a homogeneous pore distribution and a porosity of 60%. Ceramics with a pore size range of 50-100 micron and 200-400 micron were compared. Morphometric analysis showed that up to 85.4% of the originally implanted tricalcium phosphate was degraded after six months, whereas the volume reduction of the hydroxyapatite was only 5.4% after the same period. Within the first months bone and tissue ingrowth and implant resorption occurred at a higher rate in the smaller-pored tricalcium phosphate than in the larger-pored material. Hydroxyapatite cylinders with small pores were totally infiltrated by bone or bone marrow after four months, whereas in the larger-pored hydroxyapatite implants tissue did not penetrate all pores after six months and the amount of bone within the implant was small. Scanning electron microscopy of the material before implantation revealed the existence of numerous pore interconnections with diameters of about 20 micron in the smaller-pored ceramics. Such interconnections were rare in the larger-pored implants. The pore interconnections seem to promote vascular and tissue ingrowth and consequently the initial rate of implant resorption. Implant resorption is an active process and involves two different cell types. Acid phosphatase-positive osteoclast-like cells suggesting active resorption adhere directly to the surface, especially in tricalcium phosphate implants. Clusters of macrophages tightly packed with granular material are found in the pores and along the perimeter of all implant cylinders. They may play an active role in the intracellular degradation of small detached ceramic particles.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 2838207

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  69 in total

1.  Biphasic synthetic bone substitute use in orthopaedic and trauma surgery: clinical, radiological and histological results.

Authors:  C Schwartz; P Liss; B Jacquemaire; P Lecestre; P Frayssinet
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

2.  Osseointegration and osseoconductivity of hydroxyapatite of different microporosities.

Authors:  A L Rosa; M M Beloti; P T Oliveira; R Van Noort
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

3.  Biomechanical assessment of bone ingrowth in porous hydroxyapatite.

Authors:  K A Hing; S M Best; K E Tanner; W Bonfield; P A Revell
Journal:  J Mater Sci Mater Med       Date:  1997-12       Impact factor: 3.896

4.  Bone formation induced by calcium phosphate ceramics in soft tissue of dogs: a comparative study between porous alpha-TCP and beta-TCP.

Authors:  H Yuan; J D De Bruijn; Y Li; J Feng; Z Yang; K De Groot; X Zhang
Journal:  J Mater Sci Mater Med       Date:  2001-01       Impact factor: 3.896

5.  Porous hydroxyapatite ceramics of bi-modal pore size distribution.

Authors:  V S Komlev; S M Barinov
Journal:  J Mater Sci Mater Med       Date:  2002-03       Impact factor: 3.896

6.  Development of porous HAp and β-TCP scaffolds by starch consolidation with foaming method and drug-chitosan bilayered scaffold based drug delivery system.

Authors:  B Kundu; A Lemos; C Soundrapandian; P S Sen; S Datta; J M F Ferreira; D Basu
Journal:  J Mater Sci Mater Med       Date:  2010-07-20       Impact factor: 3.896

7.  Mesenchymal stem cell (MSC) and endothelial progenitor cell (EPC) growth and adhesion in six different bone graft substitutes.

Authors:  J Schultheiss; C Seebach; D Henrich; K Wilhelm; J H Barker; J Frank
Journal:  Eur J Trauma Emerg Surg       Date:  2011-06-07       Impact factor: 3.693

8.  Microporosity enhances bioactivity of synthetic bone graft substitutes.

Authors:  K A Hing; B Annaz; S Saeed; P A Revell; T Buckland
Journal:  J Mater Sci Mater Med       Date:  2005-05       Impact factor: 3.896

9.  Macroporous calcium phosphate glass-ceramic prepared by two-step pressing technique and using sucrose as a pore former.

Authors:  Cong Wang; Toshihiro Kasuga; Masayuki Nogami
Journal:  J Mater Sci Mater Med       Date:  2005-08       Impact factor: 3.896

10.  Lumbar spine interbody fusion with reinforced hydroxyapatite implants.

Authors:  P Ylinen; J Kinnunen; E M Laasonen; A Lamminen; S Vainionpää; M Raekallio; P Rokkanen; P Törmälä
Journal:  Arch Orthop Trauma Surg       Date:  1991       Impact factor: 3.067