Literature DB >> 28379404

A prospective study of external stenting of saphenous vein grafts to the right coronary artery: the VEST II study.

David P Taggart1,2, Sanaz Amin1,2, Jasmina Djordjevic2, Evangelos K Oikonomou3, Sheena Thomas3, Anna-Maria Kampoli4, Nikant Sabharwal1,3, Charalambos Antoniades1,3, George Krasopoulos1,2.   

Abstract

OBJECTIVES: External stents significantly reduce intimal hyperplasia and improve lumen uniformity and flow pattern in saphenous vein grafts (SVG) 1 year after coronary artery bypass grafting. However, recent studies have shown that at 1 year there is a lower patency of externally stented SVG to the right coronary artery (RCA) (55-60%) when compared to the left sided coronary arteries (85-90%). In the current study, we investigated whether avoidance of both fixation of the external stent to the anastomoses and the use of metal clips to ligate SVG side branches would improve the early patency of externally stented SVG to the RCA.
METHODS: Thirty patients received a SVG to the right territory supported with an external stent. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG patency assessed by computed tomography angiography (CTA) at 3-6 months. Graft failure was defined as > 50% stenosis.
RESULTS: Twenty-nine patients (96.6%) completed the follow up period and CT angiography data was available for a total of 43 SVGs, (29 supported and 14 unsupported SVGs) and 47 arterial grafts. Patency of stented SVGs was 86.2% (25/29 on CTA). All non-stented SVGs to the left territory were patent. Patency rates of the left internal mammary arteries and right internal mammary arteries grafts were 96.6% and 83.3%, respectively.
CONCLUSIONS: Avoidance of both metallic clips to ligate side branches and of fixation of venous external support trial (VEST) stents to the anastomoses mark a significant improvement in patency of stented SVG to the right coronary territory.
© The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  CT angiography; Coronary artery bypass surgery; External stenting; Graft patency

Mesh:

Year:  2017        PMID: 28379404     DOI: 10.1093/ejcts/ezw438

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  4 in total

Review 1.  Twenty-Five Years of No-Touch Saphenous Vein Harvesting for Coronary Artery Bypass Grafting: Structural Observations and Impact on Graft Performance.

Authors:  Ninos Samano; Domingos Souza; Bruno Botelho Pinheiro; Tomislav Kopjar; Michael Dashwood
Journal:  Braz J Cardiovasc Surg       Date:  2020-02-01

2.  The evolving evidence base for coronary artery bypass grafting and arterial grafting in 2021: How to improve vein graft patency.

Authors:  Dominique Vervoort; Abdullah Malik; Stephen E Fremes
Journal:  JTCVS Tech       Date:  2021-09-24

3.  Effects of the different-sized external stents on vein graft intimal hyperplasia and inflammation.

Authors:  Qi Yang; Dong Lei; Shixing Huang; Yi Yang; Yang Yang; Xiaofeng Ye; Zhengwei You; Qiang Zhao
Journal:  Ann Transl Med       Date:  2020-02

4.  Long-term performance of an external stent for saphenous vein grafts: the VEST IV trial.

Authors:  David P Taggart; Carolyn M Webb; Anthony Desouza; Rashmi Yadav; Keith M Channon; Fabio De Robertis; Carlo Di Mario
Journal:  J Cardiothorac Surg       Date:  2018-11-19       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.