Literature DB >> 28379155

Beam-on imaging of short-lived positron emitters during proton therapy.

H J T Buitenhuis1, F Diblen, K W Brzezinski, S Brandenburg, P Dendooven.   

Abstract

In vivo dose delivery verification in proton therapy can be performed by positron emission tomography (PET) of the positron-emitting nuclei produced by the proton beam in the patient. A PET scanner installed in the treatment position of a proton therapy facility that takes data with the beam on will see very short-lived nuclides as well as longer-lived nuclides. The most important short-lived nuclide for proton therapy is 12N (Dendooven et al 2015 Phys. Med. Biol. 60 8923-47), which has a half-life of 11 ms. The results of a proof-of-principle experiment of beam-on PET imaging of short-lived 12N nuclei are presented. The Philips Digital Photon Counting Module TEK PET system was used, which is based on LYSO scintillators mounted on digital SiPM photosensors. A 90 MeV proton beam from the cyclotron at KVI-CART was used to investigate the energy and time spectra of PET coincidences during beam-on. Events coinciding with proton bunches, such as prompt gamma rays, were removed from the data via an anti-coincidence filter with the cyclotron RF. The resulting energy spectrum allowed good identification of the 511 keV PET counts during beam-on. A method was developed to subtract the long-lived background from the 12N image by introducing a beam-off period into the cyclotron beam time structure. We measured 2D images and 1D profiles of the 12N distribution. A range shift of 5 mm was measured as 6  ±  3 mm using the 12N profile. A larger, more efficient, PET system with a higher data throughput capability will allow beam-on 12N PET imaging of single spots in the distal layer of an irradiation with an increased signal-to-background ratio and thus better accuracy. A simulation shows that a large dual panel scanner, which images a single spot directly after it is delivered, can measure a 5 mm range shift with millimeter accuracy: 5.5  ±  1.1 mm for 1  ×  108 protons and 5.2  ±  0.5 mm for 5  ×  108 protons. This makes fast and accurate feedback on the dose delivery during treatment possible.

Entities:  

Mesh:

Year:  2017        PMID: 28379155     DOI: 10.1088/1361-6560/aa6b8c

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

2.  Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.

Authors:  F Hueso-González; T Bortfeld
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-07-23

3.  Roadmap toward the 10 ps time-of-flight PET challenge.

Authors:  Paul Lecoq; Christian Morel; John O Prior; Dimitris Visvikis; Stefan Gundacker; Etiennette Auffray; Peter Križan; Rosana Martinez Turtos; Dominique Thers; Edoardo Charbon; Joao Varela; Christophe de La Taille; Angelo Rivetti; Dominique Breton; Jean-François Pratte; Johan Nuyts; Suleman Surti; Stefaan Vandenberghe; Paul Marsden; Katia Parodi; Jose Maria Benlloch; Mathieu Benoit
Journal:  Phys Med Biol       Date:  2020-10-22       Impact factor: 3.609

4.  Radioactive Beams for Image-Guided Particle Therapy: The BARB Experiment at GSI.

Authors:  Daria Boscolo; Daria Kostyleva; Mohammad Javad Safari; Vasiliki Anagnostatou; Juha Äystö; Soumya Bagchi; Tim Binder; Georgios Dedes; Peter Dendooven; Timo Dickel; Vasyl Drozd; Bernhard Franczack; Hans Geissel; Chiara Gianoli; Christian Graeff; Tuomas Grahn; Florian Greiner; Emma Haettner; Roghieh Haghani; Muhsin N Harakeh; Felix Horst; Christine Hornung; Jan-Paul Hucka; Nasser Kalantar-Nayestanaki; Erika Kazantseva; Birgit Kindler; Ronja Knöbel; Natalia Kuzminchuk-Feuerstein; Bettina Lommel; Ivan Mukha; Chiara Nociforo; Shunki Ishikawa; Giulio Lovatti; Munetaka Nitta; Ikechi Ozoemelam; Stephane Pietri; Wolfgang R Plaß; Andrej Prochazka; Sivaji Purushothaman; Claire-Anne Reidel; Heidi Roesch; Fabio Schirru; Christoph Schuy; Olga Sokol; Timo Steinsberger; Yoshiki K Tanaka; Isao Tanihata; Peter Thirolf; Walter Tinganelli; Bernd Voss; Uli Weber; Helmut Weick; John S Winfield; Martin Winkler; Jianwei Zhao; Christoph Scheidenberger; Katia Parodi; Marco Durante
Journal:  Front Oncol       Date:  2021-08-19       Impact factor: 5.738

Review 5.  Latest developments in in-vivo imaging for proton therapy.

Authors:  Katia Parodi
Journal:  Br J Radiol       Date:  2019-12-12       Impact factor: 3.039

6.  Biomedical Research Programs at Present and Future High-Energy Particle Accelerators.

Authors:  Vincenzo Patera; Yolanda Prezado; Faical Azaiez; Giuseppe Battistoni; Diego Bettoni; Sytze Brandenburg; Aleksandr Bugay; Giacomo Cuttone; Denis Dauvergne; Gilles de France; Christian Graeff; Thomas Haberer; Taku Inaniwa; Sebastien Incerti; Elena Nasonova; Alahari Navin; Marco Pullia; Sandro Rossi; Charlot Vandevoorde; Marco Durante
Journal:  Front Phys       Date:  2020-10-16

7.  Proton range verification with MACACO II Compton camera enhanced by a neural network for event selection.

Authors:  Enrique Muñoz; Ana Ros; Marina Borja-Lloret; John Barrio; Peter Dendooven; Josep F Oliver; Ikechi Ozoemelam; Jorge Roser; Gabriela Llosá
Journal:  Sci Rep       Date:  2021-04-29       Impact factor: 4.379

Review 8.  Roadmap: proton therapy physics and biology.

Authors:  Harald Paganetti; Chris Beltran; Stefan Both; Lei Dong; Jacob Flanz; Keith Furutani; Clemens Grassberger; David R Grosshans; Antje-Christin Knopf; Johannes A Langendijk; Hakan Nystrom; Katia Parodi; Bas W Raaymakers; Christian Richter; Gabriel O Sawakuchi; Marco Schippers; Simona F Shaitelman; B K Kevin Teo; Jan Unkelbach; Patrick Wohlfahrt; Tony Lomax
Journal:  Phys Med Biol       Date:  2021-02-26       Impact factor: 4.174

9.  New Digital Plug and Imaging Sensor for a Proton Therapy Monitoring System Based on Positron Emission Tomography.

Authors:  Nicola D'Ascenzo; Min Gao; Emanuele Antonecchia; Paolo Gnudi; Hsien-Hsin Chen; Fang-Hsin Chen; Ji-Hong Hong; Ing-Tsung Hsiao; Tzu-Chen Yen; Weidong Wang; Daoming Xi; Bo Zhang; Qingguo Xie
Journal:  Sensors (Basel)       Date:  2018-09-08       Impact factor: 3.576

10.  Radioactive Beams in Particle Therapy: Past, Present, and Future.

Authors:  Marco Durante; Katia Parodi
Journal:  Front Phys       Date:  2020-08-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.