Literature DB >> 28378908

The effect of low ventilation rate with elevated bioeffluent concentration on work performance, perceived indoor air quality, and health symptoms.

H Maula1,2, V Hongisto1,2, V Naatula1,3, A Haapakangas1,2, H Koskela1,2.   

Abstract

The aim of this laboratory experiment was to study the effects of ventilation rate, and related changes in air quality, predominantly bioeffluents, on work performance, perceived indoor air quality, and health symptoms in a typical conditions of modern open-plan office with low material and equipment emissions. In Condition A, outdoor air flow rate of 28.2 l/s person (CO2 level 540 ppm) was applied and in Condition B, outdoor air flow rate was 2.3 l/s person (CO2 level 2260 ppm). CO2 concentration level was used as an indicator of bioeffluents. Performance was measured with seven different tasks which measure different cognitive processes. Thirty-six subjects participated in the experiment. The exposure time was 4 hours. Condition B had a weak negative effect on performance only in the information retrieval tasks. Condition B increased slightly subjective workload and perceived fatigue. No effects on health symptoms were found. The intensity of symptoms was low in both conditions. The experimental condition had an effect on perceived air quality and observed odor intensity only in the beginning of the session. Although the room temperature was controlled in both conditions, the heat was perceived to impair the performance more in Condition B.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  CO2 concentration; air quality; cognitive performance; human bioeffluents; open-plan offices; perceived fatigue

Mesh:

Substances:

Year:  2017        PMID: 28378908     DOI: 10.1111/ina.12387

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  2 in total

Review 1.  Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services.

Authors:  Paolo Carrer; Peder Wolkoff
Journal:  Int J Environ Res Public Health       Date:  2018-04-12       Impact factor: 3.390

2.  Relationships Between Short-Term Exposure to an Indoor Environment and Dry Eye (DE) Symptoms.

Authors:  Maria A Idarraga; Juan S Guerrero; Samantha G Mosle; Frank Miralles; Anat Galor; Naresh Kumar
Journal:  J Clin Med       Date:  2020-05-02       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.