Literature DB >> 28377186

Reliability, construct validity and determinants of 6-minute walk test performance in patients with chronic heart failure.

Nicole H M K Uszko-Lencer1, Rafael Mesquita2, Eefje Janssen3, Christ Werter4, Hans-Peter Brunner-La Rocca5, Fabio Pitta6, Emiel F M Wouters2, Martijn A Spruit3.   

Abstract

BACKGROUND: In-depth analyses of the measurement properties of the 6-minute walk test (6MWT) in patients with chronic heart failure (CHF) are lacking. We investigated the reliability, construct validity, and determinants of the distance covered in the 6MWT (6MWD) in CHF patients.
METHODS: 337 patients were studied (median age 65years, 70% male, ejection fraction 35%). Participants performed two 6MWTs on subsequent days. Demographics, anthropometrics, clinical data, ejection fraction, maximal exercise capacity, body composition, lung function, and symptoms of anxiety and depression were also assessed. Construct validity was assessed in terms of convergent, discriminant and known-groups validity. Stepwise linear regression was used.
RESULTS: 6MWT was reliable (ICC=0.90, P<0.0001). The learning effect was 31m (95%CI 27, 35m). Older age (≥65years), lower lung diffusing capacity (<80% predicted) and higher NYHA class (NYHA III) were associated with a lower likelihood of a meaningful increase in the second test (OR 0.45-0.56, P<0.05 for all). The best 6MWD had moderate-to-good correlations with peak exercise capacity (rs=0.54-0.69) and no-to-fair correlations with body composition, lung function, ejection fraction, and symptoms of anxiety and depression (rs=0.04-0.49). Patients with higher NYHA classes had lower 6MWD. 6MWD was independently associated with maximal power output during maximal exercise, estimated glomerular filtration rate and age (51.7% of the variability).
CONCLUSION: 6MWT was found to be reliable and valid in patients with mild-to-moderate CHF. Maximal exercise capacity, renal function and age were significant determinants of the best 6MWD. These findings strengthen the clinical utility of the 6MWT in CHF.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Exercise test; Heart failure; Reliability of results

Mesh:

Year:  2017        PMID: 28377186     DOI: 10.1016/j.ijcard.2017.02.109

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  26 in total

Review 1.  Non-response to Cardiac Resynchronization Therapy.

Authors:  Syed Yaseen Naqvi; Anas Jawaid; Ilan Goldenberg; Valentina Kutyifa
Journal:  Curr Heart Fail Rep       Date:  2018-10

2.  Association Between the 6-Minute Walk Test Distance and Peak Cardiorespiratory Fitness Among People Living with HIV Varies by Fitness Level.

Authors:  Vitor H F Oliveira; Joseph D Perazzo; Richard A Josephson; Rafael Deminice; Allison R Webel
Journal:  J Assoc Nurses AIDS Care       Date:  2018-06-04       Impact factor: 1.354

3.  The importance of physical performance in the assessment of patients on haemodialysis: A survival analysis.

Authors:  Karsten Vanden Wyngaert; Wim Van Biesen; Sunny Eloot; Amaryllis H Van Craenenbroeck; Patrick Calders; Els Holvoet
Journal:  PLoS One       Date:  2022-05-19       Impact factor: 3.752

4.  Efficacy of an asynchronous telerehabilitation program in post-COVID-19 patients: A protocol for a pilot randomized controlled trial.

Authors:  Beatriz Carpallo-Porcar; Laura Romo-Calvo; Sara Pérez-Palomares; Carolina Jiménez-Sánchez; Pablo Herrero; Natalia Brandín-de la Cruz; Sandra Calvo
Journal:  PLoS One       Date:  2022-07-19       Impact factor: 3.752

5.  Assessment of Exercise Capacity and Oxygen Consumption Using a 6 min Stepper Test in Older Adults.

Authors:  Siana Jones; Therese Tillin; Suzanne Williams; Emma Coady; Nishi Chaturvedi; Alun D Hughes
Journal:  Front Physiol       Date:  2017-06-14       Impact factor: 4.566

6.  The Chinese (Mandarin) instructions of the 6-minute walk test: A validation study.

Authors:  Vivian Z Tan; Meredith Q Lee; Daryl L Wong; Katherin S Huang; Melissa Y Chan; Clement C Yan; Meredith T Yeung
Journal:  Hong Kong Physiother J       Date:  2021-01-13

7.  Establishing a cardiac training group for patients with heart failure: the "HIP-in-Würzburg" study.

Authors:  Gülmisal Güder; Joana Wilkesmann; Nina Scholz; Robert Leppich; Peter Düking; Billy Sperlich; Christian Rost; Stefan Frantz; Caroline Morbach; Floran Sahiti; Ulrich Stefenelli; Margret Breunig; Stefan Störk
Journal:  Clin Res Cardiol       Date:  2021-06-22       Impact factor: 5.460

8.  Validation of exhaled volatile organic compounds analysis using electronic nose as index of COPD severity.

Authors:  Panaiotis Finamore; Claudio Pedone; Simone Scarlata; Alessandra Di Paolo; Simone Grasso; Marco Santonico; Giorgio Pennazza; Raffaele Antonelli Incalzi
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2018-05-01

9.  Markers of protein-energy wasting and physical performance in haemodialysis patients: A cross-sectional study.

Authors:  Karsten Vanden Wyngaert; Bert Celie; Patrick Calders; Sunny Eloot; Els Holvoet; Wim Van Biesen; Amaryllis H Van Craenenbroeck
Journal:  PLoS One       Date:  2020-07-30       Impact factor: 3.240

10.  Predictors of functional improvement in the short term after MitraClip implantation in patients with secondary mitral regurgitation.

Authors:  Michael G Paulus; Christine Meindl; Lukas Böhm; Magdalena Holzapfel; Michael Hamerle; Christian Schach; Lars S Maier; Kurt Debl; Bernhard Unsöld; Christoph Birner
Journal:  PLoS One       Date:  2020-05-28       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.