Literature DB >> 28372955

Colloids in Cardiac Surgery-Friend or Foe?

Pia Katarina Ryhammer1, Mariann Tang2, Joachim Hoffmann-Petersen3, Dovile Leonaviciute4, Jacob Greisen1, Marie Storebjerg Gissel1, Carl-Johan Jakobsen5.   

Abstract

OBJECTIVE: The right choice of fluid replacement still is a matter of debate. Recently, two large-scale studies on the use of hydroxyethyl starches (HES) in the intensive care setting have been published, which have caused a huge shift in the daily practice of volume therapy. These results have been applied to patients outside intensive care. The aim of this study was to evaluate the impact this change has had on the outcomes in a large population of cardiac surgery patients, with a focus on the type of colloid infusion.
DESIGN: A prospective, registered, observational study, using propensity score matching.
SETTING: Cohort study from 3 university hospitals using a common registry. PARTICIPANTS: The study comprised 17,742 patients who were referred for cardiac surgery from 2007 to 2014.
INTERVENTIONS: Patients were divided in groups according to perioperative fluid replacement with either crystalloids or colloids. The colloid group was further divided into HES or human albumin (HA). Analyses were based on the following 3 subsections: HES versus crystalloids, HA versus crystalloids, and HES versus HA, with use of propensity score matching or direct matching of cases. Primary outcome parameters were 30-day and 6-month mortality, new postoperative renal replacement therapy, and new cardiac ischemic events.
MEASUREMENTS AND MAIN RESULTS: The groups were fully comparable in individual analyses. The use of HES had no impact on new dialysis and 30-day mortality. A Cox proportional regression analysis showed that HES had no impact on 6-month mortality and new postoperative ischemic events. When comparing HA with crystalloid use, a significantly increased risk in crude analysis was demonstrated on all outcome parameters; and when comparing HA with HES, a significantly higher risk was observed in HA patients in mortality parameters and new postoperative, but after adjustment, only the risk of new postoperative dialysis persisted.
CONCLUSION: This study underlined the difficulties in establishing hardcore outcome data, even in large cohort studies. The findings seemed to diminish the magnitude of risk when using HES in cardiac surgery patients and seriously questioned the choice of HA when a plasma expander is needed.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cardiac recovery; cardiac surgery; dialysis; human albumin; hydroxyethyl starch; ischemic heart disease

Mesh:

Substances:

Year:  2017        PMID: 28372955     DOI: 10.1053/j.jvca.2017.02.001

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  4 in total

1.  Consensus Report on Patient Blood Management in Cardiac Surgery by Turkish Society of Cardiovascular Surgery (TSCVS), Turkish Society of Cardiology (TSC), and Society of Cardio-Vascular-Thoracic Anaesthesia and Intensive Care (SCTAIC).

Authors:  Serkan Ertugay; Türkan Kudsioğlu; Taner Şen
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2019-10-23       Impact factor: 0.332

Review 2.  Albumin in adult cardiac surgery: a narrative review.

Authors:  Ciara Hanley; Jeannie Callum; Keyvan Karkouti; Justyna Bartoszko
Journal:  Can J Anaesth       Date:  2021-04-21       Impact factor: 6.713

3.  Effect of 6% hydroxyethyl starch 130/0.4 on kidney and haemostatic function in cardiac surgical patients: a randomised controlled trial.

Authors:  A E Duncan; Y Jia; E Soltesz; S Leung; H O Yilmaz; G Mao; A A Timur; K Kottke-Marchant; H J Rogers; C Ma; I Ince; N Karimi; S Yagar; C Trombetta; D I Sessler
Journal:  Anaesthesia       Date:  2020-02-18       Impact factor: 12.893

4.  Impact of 6% balanced hydroxyethyl starch following cardiopulmonary bypass on renal function: a retrospective study.

Authors:  Ju Yong Lim; Yun Seok Kim; Joon Bum Kim
Journal:  J Cardiothorac Surg       Date:  2020-09-07       Impact factor: 1.637

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.