Literature DB >> 28371125

Comparison of bleb morphology between trabeculectomy and deep sclerectomy using a clinical grading scale and anterior segment optical coherence tomography.

Lawrence J Oh1,2, Eugene Wong3, Julie Lam4, Colin I Clement4,5,2.   

Abstract

IMPORTANCE: The role of the filtration bleb for IOP management following trabeculectomy (TRAB) and deep sclerectomy (DS) in glaucoma is highlighted in this study.
BACKGROUND: This study serves to analyse the bleb morphology and IOP using the Indiana Bleb Appearance Grading Scale (IBAGS) and the anterior-segment optical coherence tomography (AS-OCT) postoperatively and at 3 months.
DESIGN: The retrospective study was performed by a single surgeon. PARTICIPANTS: Twenty-eight patients with open-angle glaucoma were recruited into the study, 14 in each of the TRAB (fornix) and DS groups.
METHODS: The surgical intervention was dependent on the irido-corneal angle configuration on gonioscopy. MAIN OUTCOME MEASURES: Pre-operatively, we collected visual acuity, medications and IOP. Three months postoperatively, we used the IBAGS to assess bleb morphology, including bleb height, extent, vascularity and leak. AS-OCT was also used to assess bleb height, thickness, cyst presence and posterior and intrascleral fluid.
RESULTS: Central corneal thickness and mean IOP at 3 months postoperatively were significantly lower in the TRAB group (7.75 vs. 12.27 mmHg; P = 0.005). Blebs that were significantly higher, broader and less vascular compared with DS were displayed by TRAB eyes. The AS-OCT measurements confirmed TRAB eyes had significantly higher blebs and increased intrascleral fluid compared with DS eyes. CONCLUSIONS AND RELEVANCE: Significant differences in bleb morphology, correlating with improved IOP outcomes in TRAB eyes compared with DS eyes in patients with open-angle glaucoma, were showed by both the IBAGS and AS-OCT. Despite the limitations of each classification system, a higher bleb with an increased aqueous reservoir is associated with optimal IOP results.
© 2017 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  filtering blebs; glaucoma; trabeculectomy

Mesh:

Year:  2017        PMID: 28371125     DOI: 10.1111/ceo.12953

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  4 in total

1.  Comparison of conjunctival vascularity changes using optical coherence tomography angiography after trabeculectomy and phacotrabeculectomy.

Authors:  Je Hyun Seo; Young Lee; Jong Hoon Shin; Ye An Kim; Keun Heung Park
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-07-10       Impact factor: 3.117

2.  Effect of filtering bleb dimensions on postoperative intraocular pressure in deep sclerectomy with collagen implant: a comparative study.

Authors:  Hany Elmekawey; Ahmed Abdelrahman; Mohamad S Kotb; Diia Alden Mostafa
Journal:  Int Ophthalmol       Date:  2019-07-18       Impact factor: 2.031

3.  Evaluation of Functional Filtering Bleb Using Optical Coherence Tomography Angiography.

Authors:  Je Hyun Seo; Ye An Kim; Keun Heung Park; Young Lee
Journal:  Transl Vis Sci Technol       Date:  2019-05-06       Impact factor: 3.283

4.  The CLASS Surgical Site Characteristics in a Clinical Grading Scale and Anterior Segment Optical Coherence Tomography: A One-Year Follow-Up.

Authors:  Judyta Jankowska-Szmul; Edward Wylegala
Journal:  J Healthc Eng       Date:  2018-05-15       Impact factor: 2.682

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.