6-mm-long implants loaded with fiber-reinforced composite resin-bonded fixed prostheses (FRCRBFDPs). A 5-year prospective study.

Fabio Rossi1,2, Niklaus P Lang3,4, Emanuele Ricci1, Lorenzo Ferraioli1, Claudio Marchetti5, Daniele Botticelli2,6.   

Abstract

AIM: To evaluate the clinical and radiographic outcomes and the survival rates of fiber-reinforced composite resin-bonded fixed prostheses (FRCRBFDPs) placed in the posterior area supported by two short (6 mm) implants.
MATERIALS AND METHODS: Twenty consecutive patients received 40 SLActive 6-mm-long implants with a diameter of 4.1 mm (n = 29) or 4.8 mm (n = 11). Insertion torques and RFA (Resonance Frequency Analysis) were measured at implant installation. The prosthetic rehabilitation was performed after 8 weeks from insertion with a screw-retained two- or three-unit fixed dental prosthesis fabricated of FRCRBFDPs. Implant survival rates and marginal bone levels were evaluated at various time intervals until 5 years after loading.
RESULTS: Two of 20 patients lost four implants supporting two FRCRBFDPs between the second and the third year of follow-up (cumulative survival rate: 90% after 5 years). Four patients suffered a fracture of the prosthetic reconstruction, and the success rate of the rehabilitation was 70% after 5 years. A mean marginal bone loss of 0.30 ± 0.34 mm was found after 5 years of function at the remaining implants.
CONCLUSION: The survival of short implants was 90% owing to two bridges losses in the maxilla. However, the success rate of FRCRBFDPs over 5 years was only at 70%.
© 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  dental implants; early loading; fiber-reinforced resin-bonded; fixed partial dentures; implant length; prospective study; short implants

Mesh:

Substances:

Year:  2017        PMID: 28370406     DOI: 10.1111/clr.13015

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  3 in total

1.  Using Resonance Frequency Analysis to Compare Delayed and Immediate Progressive Loading for Implants Placed in the Posterior Maxilla: A Pilot Study.

Authors:  Mohammed Jasim Al Juboori; Mohammed Ahmed Al Attas; Raquel Zita Gomes; Basma Fathi Alanbari
Journal:  Open Dent J       Date:  2018-10-18

2.  CT-based dentulous mandibular alveolar ridge measurements as predictors of crown-to-implant ratio for short and extra short dental implants.

Authors:  Francesco Cavallin; Stefano Sivolella; Silvia Meggiorin; Nadia Ferrarese; Amalia Lupi; Antonino Fiorino; Chiara Giraudo
Journal:  Sci Rep       Date:  2020-10-01       Impact factor: 4.379

Review 3.  Clinical Comparation of Extra-Short (4 mm) and Long (>8 mm) Dental Implants Placed in Mandibular Bone: A Systematic Review and Metanalysis.

Authors:  Vittorio Moraschini; Carlos Fernando de Almeida Barros Mourão; Pietro Montemezzi; Ingrid Chaves Cavalcante Kischinhevsky; Daniel Costa Ferreira de Almeida; Kayvon Javid; Jamil Awad Shibli; José Mauro Granjeiro; Monica Diuana Calasans-Maia
Journal:  Healthcare (Basel)       Date:  2021-03-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.