Stephanie Oberfoell1, David Murphy2, Andrew French2,3, Stacy Trent2,3, David Richards2,3. 1. Denver Health Residency in Emergency Medicine, Denver, Colorado, USA. 2. University of Colorado Denver School of Medicine, Aurora, Colorado, USA. 3. Denver Health and Hospital Authority, Department of Emergency Medicine, Denver, Colorado, USA.
Abstract
OBJECTIVES: To compare the degree of agreement of sonographic optic nerve sheath diameter (ONSD) measurements by ultrasound fellowship-trained and resident emergency medicine (EM) physicians. METHODS: Ten ultrasound fellowship-trained EM attending physicians from multiple institutions and 51 resident EM physicians at a single residency were enrolled to measure the ONSD using a computerized ruler on five separate still-frame sonograms of adult eyes that included the retrobulbar optic nerve. Descriptive and bivariate statistics for each ultrasound image were calculated to compare median ONSD measurements among groups. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability. RESULTS: Although the median ONSD measurement of each image did not significantly differ between resident and ultrasound fellowship-trained EM physicians, we found greater variation in agreement of ONSD measurements by resident EM physicians (ICC 0.50; 95% confidence interval 0.25-0.89) than ultrasound fellowship-trained EM physicians (ICC 0.73; 95% confidence interval 0.44-0.96). CONCLUSIONS: Although both resident and ultrasound fellowship-trained EM physicians showed good inter-rater reliability of ONSD measurements, variation in agreement among ultrasound fellowship-trained EM physicians may be as wide as 0.44, suggesting that even in skilled hands, ultrasound measurement of the ONSD may not be as dependable a screening tool for elevated intracranial pressure as previously suggested in the literature.
OBJECTIVES: To compare the degree of agreement of sonographic optic nerve sheath diameter (ONSD) measurements by ultrasound fellowship-trained and resident emergency medicine (EM) physicians. METHODS: Ten ultrasound fellowship-trained EM attending physicians from multiple institutions and 51 resident EM physicians at a single residency were enrolled to measure the ONSD using a computerized ruler on five separate still-frame sonograms of adult eyes that included the retrobulbar optic nerve. Descriptive and bivariate statistics for each ultrasound image were calculated to compare median ONSD measurements among groups. Intraclass correlation coefficients (ICCs) were calculated to estimate the inter-rater reliability. RESULTS: Although the median ONSD measurement of each image did not significantly differ between resident and ultrasound fellowship-trained EM physicians, we found greater variation in agreement of ONSD measurements by resident EM physicians (ICC 0.50; 95% confidence interval 0.25-0.89) than ultrasound fellowship-trained EM physicians (ICC 0.73; 95% confidence interval 0.44-0.96). CONCLUSIONS: Although both resident and ultrasound fellowship-trained EM physicians showed good inter-rater reliability of ONSD measurements, variation in agreement among ultrasound fellowship-trained EM physicians may be as wide as 0.44, suggesting that even in skilled hands, ultrasound measurement of the ONSD may not be as dependable a screening tool for elevated intracranial pressure as previously suggested in the literature.
Authors: Julia Dixon; Grant Comstock; Jennifer Whitfield; David Richards; Taylor W Burkholder; Noel Leifer; Nee-Kofi Mould-Millman; Emilie J Calvello Hynes Journal: Afr J Emerg Med Date: 2020-06-16
Authors: Casey L Wilson; Samuel Madden Leaman; Clay O'Brien; Daniel Savage; Leslie Hart; Dietrich Jehle Journal: J Am Coll Emerg Physicians Open Date: 2021-01-04
Authors: Jason B Jennings; Cynthia Oliva; Michael Joyce; Michael J Vitto; Jordan Tozer; Lindsay A Taylor; David P Evans Journal: Ultrasound J Date: 2022-01-10